F238000
19
Section 4 Service Procedures
To reduce the risk of electrical shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer-extractor before servicing.
• Never start the washer-extractor with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer-extractor is properly grounded.
W171
WARNING
26. CONTACTORS
IMPORTANT: Before removing wires from
contactors, mark the terminal contactors and the
wire number so wires can be reinstalled correctly.
a. Insert key into cabinet top lock and turn
clockwise. Lift up on front of cabinet top until
it is just past the rear hinges, or 90 degrees, refer
to
. Lift cabinet top off machine and set
out of way.
NOTE: When reinstalling cabinet top, metal edges
on dispenser opening must be fitted inside of
dispenser.
b. Remove two T20 Torx head screws from
control module box cover. Lift up cover and set
aside.
c. Pull spring clip on bottom of contactor and
remove contactor from control module box,
refer to
Figure 8
B008SE1A
SPRING
CLIP
CONTACTOR