M411429
35
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
38. CG OM MODELS: NO HEAT WITH CYCLE SELECTED, UNIT RUNNING AND CALLING FOR
HEAT
120 Volt/60 Hertz/1 Phase and 208-240 Volt/60 Hertz/1 Phase Nonreversing
460-480 Volt/60 Hertz/3 Phase and 208-240 Volt/60 Hertz/3 Phase Reversing and Nonreversing
(continued)
Step Problem
If No, then
20
Does the igniter spark? If yes, continue to next step.
Check for proper gap on igniter and check for proper
resistance of ignition cable. Replace if necessary.
21
Is there voltage at terminal 1 of the ignition control? If yes,
continue to next step.
Replace ignition control.
21
Is there voltage across the gas valve? If yes, continue to
next step.
Correct wiring to gas valve.
22
Is there a flame? If yes, continue to next step.
Check for gas flow and proper gas pressure. Replace gas
valve or coils of gas valve.
24
Unit operational.