To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70. CABINET HIGH LIMIT THERMOSTAT
(Energy Saver Gas Models)
a. Remove drive guard.
b. Disconnect wires from thermostat. Refer to
c. Remove two screws holding thermostat to
cabinet.
(Standard Models)
a. Remove lint panel.
b. Remove cover.
c. Disconnect wires from thermostat. Refer to
d. Remove two screws holding thermostat to
cabinet.
NOTE: Refer to wiring diagram when reconnecting
thermostat wires.
Figure 29
TU026-SV
STOVE
HIGH LIMIT
THERMOSTAT
MOUNTING
BRACKET
COVER
PHILLIPS
HEAD
SCREWS
PHILLIPS
HEAD
SCREWS