40
M413438
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
45. ACCUMULATOR TIMER MOTOR
a. Unlock and open access panel. Use support rod
to hold panel up.
b. Disconnect accumulator wire harness at plug.
c. Unlock service door on top of meter case.
d. Lift service door. Remove door, accumulator,
mounting bracket and wire harness from
tumbler.
e. Remove two capscrews holding accumulator
bracket to service door. Refer to Figure 11.
f. Remove two screws holding timer motor to
mounting bracket.Refer to Figure 11.
g. Hold cam and drive fork against inside face of
mounting bracket and carefully pull timer
motor out of cam hub.
h. Disconnect motor leads at wire nut and at
double spade connector on switch terminal.
i. Connect leads of new motor using new wire nut
and connector. Refer to wiring diagram for
proper connections.
Figure 11
CAPSCREW
PHILLIPS
HEAD
SCREW
SWITCH
"B"
SWITCH
"A"
SERVICE
DOOR
ACCUMULATOR
ASSEMBLY
SWITCH
BRACKET
SWITCH
ACTUATOR
MOUNTING
BRACKET
ACCUMULATOR
TIMER MOTOR
SWITCH
BRACKET
T010se2a