© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming
27
F8112301R3
18. Display shows “
xx.tENP
” (xx = temperature of
bath).
19. This is the temperature of this program step or
bath. No user input required.
20. Press Enter to continue.
21. Display shows “
F xxx
”or “
C xxx
” (xxx =
temperature).
22. Use the keypad to input the temperature desired
for this program step or bath. If no temperature
control is desired for this bath, enter “
033
” for F
°
or “
000
” for C
°
. This will allow you to specify
which main fill valves are to open.
23. Press Enter to continue.
NOTE: The next step will be determined by
“
HEAtSYS
” option chosen in Setup (Pre-Program)
Mode.
If “
HEAt-
n
od
” was chosen in Setup (Pre-Program)
Mode, select from:
•
“
HEAt
” (supplemental heating without
temperature controlled water inlet). If this
option is chosen, pressing Enter transfers
to “
no HECo
” or “
00. SE-I
”. Pressing
Temperature button transfers to “
n
od
”.
•
“
HEAt-
n
od
” (temperature controlled
water inlets with supplemental heating).
Pressing Enter transfers to “
no
HECo
” or
“
00. SE-i
”. Pressing Temperature button
transfers back to “
HEAt
”.
•
“
n
od” (temperature controlled water inlets
without supplemental heating). Pressing
Enter transfers to “
00. SE-i
”. Pressing
Temperature button transfers to “
HEAt-
n
od
”.
If “
HEAt
” was chosen during the preprogramming
or configuration process, display will automatically
go to “
no HECo
” or “
00.SE-i
”.
If “
n
od
” was chosen during the preprogramming
or configuration process, display will automatically
go to “
XX. SE-i
”.
24. Display shows “
no HECo”
or “
HECo
”. “
HECo
”
will stop program until programmed temperature
is reached.
25. Press Temperature button to alter selection.
26. Press Enter to continue.
27. Display shows “
t xx.xx
” (xx.xx = time program
stops).
28. Use the keypad to input the time of program step
where program will stop until programmed
temper is reached (use “
0
” for beginning of
program step).
29. Press Enter to continue.
30. Display shows “
noGEntLE
” or “
GEntLE
”.
“
GEntLE
” will enable cylinder to operate in
Gentle Action Mode until programmed
temperature is reached.
31. Press Temperature button to alter selection.
32. Press Enter to continue.
33. Display shows “
xx. SE-I
” (xx = water inlet
selection).
34. This is the water inlet selection made during
Setup (Pre-Program) Mode, no user input
required.
35. Press Enter to continue.
36. Display shows “
no i.1
” or “
i.1
”. “
i.1
” enables the
Powdered Supply Compartment Number 1.
37. Press Temperature button to alter selection.
38. Press Enter to continue.
39. Display shows “
no i.2
” or “
i.2
”. “
i.2
” enables the
Powdered Supply Compartment Number 2.
40. Press Temperature button to alter selection.
41. Press Enter to continue.
42. Display shows “
no i.3
” or “
i.3
”. “
i.3
” enables the
Powdered Supply Compartment Number 3.
43. Press Temperature button to alter selection.
44. Press Enter to continue.
45. Display shows “
no i.4
” or “
i.4
”. “
i.4
” enables the
Powdered Supply Compartment Number 4.
46. Press Temperature button to alter selection.
47. Press Enter to continue.
48. Display shows “
no i.5
” or “
i.5
”. “
i.5
” enables the
Powdered Supply Compartment Number 5.
49. Press Temperature button to alter selection.
50. Press Enter to continue.
51. Display shows “
no i.CoLd
” or “
i.CoLd
”.
“
i.CoLd
” enables the main cold water inlet fill
valve.
NOTE: A temperature of at least 33° for °F or 0 for
°C should be programmed (Refer to
Step 22
) so
water valves actuate for a warm (both hot and cold)
fill.
www.groupdynamics-laundry.com