Washer Will Not Fill (Mixing Valve Diagnostic)
E FL
on digital display
NOTE: Make sure unit passes pressure sensor diagnostics first. Refer to
.
Is the lid closed?
(1)
Is there voltage from
the output board to
the lid switch at
"H3-2" to "H1-4"?
Yes
Close lid.
No
(2)
Is there voltage from
the output board to
the water valves at
"H4-8" (Hot) and
"H4-7" (Cold) to
"H4-1"?
Yes
Check function of lid
switch. Replace if
needed.
No
(3)
Is there voltage at
the mixing valve
solenoids?
Yes
Replace output board.
No
Replace mixing valve.
Yes
Check harness for
damage. Replace if
needed.
No
Troubleshooting Electronic Control
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
48
Part No. 204591EN
Summary of Contents for BWNBX2PP303AW01