CHM2570N_SVG
1.
External Supply Power Output
2.
Internal Control Transformer
3.
RELAY COM Terminal
4.
External Dispenser Input Signal Common
Figure 44
CHM2571N_SVG
1.
External Supply Power Output
2.
Internal Control Transformer
3.
RELAY COM Terminal
4.
External Dispenser Input Signal Common
Figure 45
Chemical Injection Using External AC Power
Source
NOTE: An External AC Power Source is NOT provided
by Alliance Laundry Systems.
NOTE: Power for external supplies must not be derived
from the high-voltage main power connection point.
IMPORTANT: The external power must supply power of
240VAC or less and be protected at 3 Amps or less.
1. Disconnect and cap off the Red and White 24VAC wires.
2. Connect one side of the external power to the “RELAY
COM” and the other to the external dispenser input signals
common. Refer to
and
CHM2573N_SVG
1.
External Supply Power Output
2.
External Dispencer Input Signal Common
3.
Capped Off 24VAC Supply
4.
VAC Terminal
5.
VAC COM Terminal
Figure 46
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
95
Part No. F8619501ENR11