M412982
43
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
58. CYLINDER DRIVE MOTOR
Refer to Figure 20.
a. Support drive guard cover and remove screws
that hold guard to rear of tumbler. Refer to
Figure 13.
b. Remove drive belt. Refer to Figure 15.
c. Mark location of motor on the motor mounting
bracket and remove screws and nuts holding
motor to mounting bracket. Refer to Figure 20.
d. Disconnect wire harness from motor.
e. Remove motor pulley.
NOTE: Refer to wiring diagram when rewiring the
motor.
f. After installing motor, adjust drive belt tension.
Figure 20
T237PE3E
ATTACHING
SCREW
MOTOR
MOTOR
PULLEY
MOTOR
MOUNTING
BRACKET
ATTACHING
NUT