Water Supply Requirements

NOTE: Water supply faucets must fit standard 

3/4 in. (19.1 mm) female garden hose couplings. 

DO NOT USE SLIP-ON OR CLAMP-ON 

CONNECTIONS.

NOTE: Water supply faucets should be readily 

accessible to permit turning them off when washer 

is not being used.

Water Temperature

Cold:

Recommended cold water temperature is 60° to 

80° Fahrenheit (16° to 27° Celsius).

Hot:

Recommended hot water temperature is 120° to 

140° Fahrenheit (49° to 60° Celsius).

Warm:

Mixture of hot and cold water (warm water 

temperature is dependent upon the water temperature 

and the pressure of both the hot and cold water supply 

lines).

IMPORTANT: Turn off water supply faucets after 

check-out and demonstration. Owner should turn 

off water supply whenever there will be an 

extended period of non-use.

NOTE: Longer fill hoses are available (as optional 

equipment at extra cost) if the hoses (supplied with 

the washer) are not long enough for the 

installation. Order hoses as follows:

No. 20617 Fill Hose (8 ft.) (2.44 m)

No. 20618 Fill Hose (10 ft.) (3.05 m)

Water Pressure

Pressure must be a minimum of 20 to a maximum of 

120 pounds per square inch (138 to 827 kPa) static 

pressure measured at the faucet.

NOTE: Water pressure under 20 pounds per 

square inch (138 kPa) will cause an extended fill 

time in the washer and may not properly flush out 

the detergent dispenser.

Risers

Risers (or air cushions) may have to be installed if the 

pipes knock or pound when flow of water stops. The 

risers are more efficient when installed as close as 

possible to the water supply faucets (refer to 

Figure 20

).

Under certain conditions, hydrogen gas may 

be produced in a hot water system that has 

not been used for two weeks or more. 

HYDROGEN GAS IS EXPLOSIVE. If the hot 

water system has not been used for such a 

period and before using the washer, turn on 

all hot water faucets and let the water flow 

from each for several minutes. This will 

release any accumulated hydrogen gas. The 

gas is flammable. Do not smoke or use an 

open flame during this time.

W029

WARNING

FLW1973N

1

Water Supply Faucets

2

Cold Water Connection

3

Hot Water Connection

4

Fill Hoses

Figure 19 

W005I

1

Water Supply Faucets

2

Risers (Air Cushions)

Figure 20 

FLW1973N

1

2

3

WATER 
MIXING 

VALVE

4

W005I

2

1

Summary of Contents for 801455R2

Page 1: ...hers FLW1522C FLW1522C Part No 801455R2 April 2012 Keep These Instructions for Future Reference If this machine changes ownership this manual must accompany machine Para bajar una copia de estas instr...

Page 2: ......

Page 3: ...Washer 5 Step 1 Position Washer Near Installation Area 5 Step 2 Connect Fill Hoses 5 Step 3 Connect Drain Hose to Drain Receptacle 6 Step 4 Position and Level the Washer 8 Step 5 Remove the Shock Sle...

Page 4: ...ement Parts If replacement parts are required contact the source from which you purchased your washer or contact Alliance Laundry Systems Shepard Street P O Box 990 Ripon WI 54971 0990 U S A Phone 920...

Page 5: ...FLW2092N 28 in 71 1 cm 2 in 5 1 cm 17 5 in 44 8 cm 41 2 in 104 6 cm 14 3 in 36 3 cm 29 6 in 75 1 cm 31 1 in 79 cm 26 9 in 68 3 cm MODELS WITH OLD STYLE DOOR FLW2044N FLW2044N 28 in 71 1 cm 2 in 5 1 c...

Page 6: ...0 and 120 pounds per square inch 138 to 827 kPa For more detailed information refer to section on Water Supply Requirements Accessories Bag An accessories bag has been shipped inside your washer It in...

Page 7: ...ection on Water Supply Requirements before connecting fill hoses Turn on the water supply faucets and flush the lines for approximately two minutes to remove any foreign materials that could clog the...

Page 8: ...ng the hose from the retainer clamp and by removing shipping tape Find the instructions on the following pages that are appropriate for your type of drain receptacle standpipe sink wall or laundry tub...

Page 9: ...om dislodging during use Figure 7 In the Wall Installation For installations of this type the drain hose MUST be secured to one of the fill hoses using the beaded tie down strap from accessories bag N...

Page 10: ...op panel Refer to Figure 10 Tighten the locknuts securely against the washer base using the 7 8 in wrench If the locknuts are not tight washer will move out of position during operation NOTE DO NOT sl...

Page 11: ...ransport unit from front or without shipping materials installed Store the shipping materials in the bag provided in the accessories bag Save materials for use whenever the unit is moved NOTE The ship...

Page 12: ...e 13 NOTE Hoses can be connected to either nozzle 4 Refer to supply injection system instructions and label inside washer junction box cover Figure 14 for electrical connection Do not attempt to make...

Page 13: ...ug In the Washer Refer to section on Electrical Requirements and connect the washer to an electrical power source Step 9 Check Installation Refer to Installer Checklist on the back cover and make sure...

Page 14: ...into a polarized three slot effectively grounded receptacle rated 110 120 Volts AC alternating current 15 Amps Refer to Figure 18 to determine correct polarity of the wall receptacle H336I 1 Shock Sle...

Page 15: ...E CIRCUIT DO NOT OVERLOAD CIRCUITS Do not operate both a washer and gas dryer on the same circuit Use separately fused 15 Amp circuits To reduce the risk of an electric shock or fire DO NOT use an ext...

Page 16: ...ill Hose 8 ft 2 44 m No 20618 Fill Hose 10 ft 3 05 m Water Pressure Pressure must be a minimum of 20 to a maximum of 120 pounds per square inch 138 to 827 kPa static pressure measured at the faucet NO...

Page 17: ...nce Laundry Systems Shepard Street P O Box 990 Ripon WI 54971 0990 U S A Date Purchased Model Number Serial Number Dealer s Name Dealer s Address Phone Number Service Agency Service Agency Address Pho...

Page 18: ......

Page 19: ......

Page 20: ...PositionWasherNear Installation Area CHECK CHECK CHECK CHECK Position and Level the Washer D254I D254I Remove the Shock Sleeves and Shipping Brace Connect Fill Hoses CHECK W520I H336I CHECK Wipe Out I...

Reviews: