Page
8
www.allfett.net
It should not be forgotten that the grease penetration properties is variable at different
environment temperatures.
The environmental temperature around lubrication lines must be concidered. Grease properties
should be appropriate that environmental temperatures. Changing NLGI classes at diffeerent temperatures
is important to correct lubrication. If necessary, high temperature resistant lubricants should be used in some
cases.
LUBRICANT INFORMATION
Lubricant specifications can be used with ALL-600 pumps are described below. Before filling reservoir
please read carefuly these informations.
To remind that lubricants has content which may hazardous to environment. It is
important that the county specific regulations and laws on the use and disposal of
lubricants must be observed.
Keep in mind that the substances of any lubricant are harmfull to environment. Their
transport and storage require that special safety measures be taken.
Only LITHIUM based and EP additive greases must be used with in system.
It is important that the grease will be used must resistant to high pressure. Make sure the liquid
grease you are using is EP additive.
NLGI classes can be used with ALL-1 pumps are described below. Because of the flow characteristics
of grease the NLGI class range should be changed at different weather conditions and also temperature
differencies.
for
NLGI 00
grease recomended working temperature is between -30°C and -10°C
for
NLGI 0
grease recomended working temperature is between -10°C and 0°C
for
NLGI 1
grease recomended working temperature is between 0°C and 10°C
for
NLGI 2
grease recomended working temperature is between 10°C and 30°C
for
NLGI 3
grease recomended working temperature is 30°C and over
Lubricant type - GREASE
ALL-600 pumps are designed to use with in centralized lubrication systems only. It is
not suitable to use ALL-600 pump for lubricant tranfering or circulation purpose.
Lubricant will be used in the system must certainly be clean and any foreign materials
must not enter while filling.
Do not use rubber based grease in system.
Do not use grease types with graphite in system.