10
Operating Instructions
OPERATING INSTRUCTIONS (CONTINUED)
Checking for Leaks
WARNING: Before using this outdoor firepit, make sure you
Figure 1
LP Gas
Connection
LP Gas Valve
with orifice
Burner Connections
1. Make sure the regulator hose and valve connections are securely
fastened to the burner and the tank.
2 . Visually check the connection between the burner/venturi
tube and orifice.
3 . Make sure the burner/venturi tube fits over the orifice.
WARNING: Failure to inspect
this
instructions could
an explosion which can cause
4 .
5 . If the burner/venturi tube does not rest flush to the orifice, as shown,
1-866-439-9800
for assistance.
Please refer to diagram for proper installation
or follow these
(Figures 1 and 2).
a fire or
connection
cause
death, serious bodily injury or damage to property.
have read, understand and are following all information provided
in the “Important Safety information” section on page 4.
Failure to follow those instructions can cause death, serious
injury or property damage.
please contact
Figure 2
Tank/Gas Line Connection
Figure 3
Figure 4
5
Figure 5
1
.
Make 2-3 oz
.
of leak detection solution by mixing one part liquid dishwashing soap with
three parts water.
.
2 . Make sure control knobs are in the“ OFF” position (Figure 3).
3 Connect LP gas tank per
“Installing LP GasTank’’.
4 .Turn off the igniter cover and put the battery (9) inside according to
the electrode (Figure 4
).
5 . Close the firepit door panel (Figure 5).
6 . Turn LP gas tank valve to“OPEN ”.
7 . Spoon several drops of solution or use a squirt
bottle, at all “X” locations (Figures 1 and 2).
a. If any bubbles appear, turn LP gas tank valve to “CLOSED”, reconnect and re-test.
b.If you continue to see bubbles after several attempts turn LP
gas tank valve to “CLOSED” and disconnect LP gas tank, per “Disconnecting LP
Gas Tank”
.
Contact 1-866-439-9800 for assistance.
c.If no bubbles appear after one minute, turn LP gas tank valve to “CLOSED”,
wipe away solution proceed.
Lighting
Figure 6
Figure 7
WARNING:
NEVER light the burner with the cover on the outdoor firepit.
CAUTION: Keep outdoor gas appliance area clear and free from
combustible materials. gasoline and other flammable vapors and liquids.
CAUTION: DO NOT obstruct the flow of combustion and ventilation air.
CAUTION: Check and clean burner/Venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
1 . Make sure all labels, packaging and protective films have been removed from
the outdoor firepit.
2 .Check for obstructions of airflow to the burner
. Spiders, insects and webs can
clog the burner/venturi tube.
A clogged burner tube can lead to a fire.
3 . Control knob must be in the “ OFF ” position (Figure 3).
4 . Clear small area of glass bead away from the igniter cover (Figure 6).
5 .Connect LP gas tank per “Installing LP Tank” section.
6 .Turn LP gas tank valve to “OPEN”.
7 . Push and hold the electronic igniter to create sparks within the electrode,
continue to hold.
8 . Push in the control knob and turn to the “ON” position, keep holding down the
control knob to allow gas to flow for 20 seconds.
9 . After 20 seconds, release and turn control knob counter clock-wise
to adjust flame
to desired height.
10 . If ignition does not occur in 20 seconds turn burner control knob to “ OFF ” wait
5 minutes, fan with a newspaper or magazine, and repeat lighting procedure.
11 . Remove cover and lid from outdoor firepit before lighting.