PowerFlex 755T Frames 5 and 6 Conduit Box with Debris Hood and Ground Plate Kits

6. As required, insert the appropriate sized clamps into the ground plate receptacles and secure the power wires.

7. Secure the cover to the chassis as shown in 

step 1

 page 

21

.

Additional Resources

These documents contain additional information concerning related products from Rockwell Automation.

You can view or download publications at 

http://www.rockwellautomation.com/global/literature-library/overview.page

.

Resource

Description

PowerFlex 750-Series Products with TotalFORCE Control Installation Instructions, publication

750-IN100

Provides the basic steps to install PowerFlex 755TL low harmonic drives, PowerFlex 755TR 

regenerative drives, and PowerFlex 755TM drive systems.

PowerFlex 750-Series Products with TotalFORCE Control Technical Data, publicatio

750-TD100

Provides detailed information on:

• Drive and bus supply specifications

• Option specifications

• Fuse and circuit breaker ratings

 PowerFlex 750-Series Products with TotalFORCE Control Hardware Service Manual, publication

750-TG100

Provides detailed information on:

• Preventive maintenance

• Component testing

• Hardware replacement procedures

Industry Installation Guidelines for Pulse Width Modulated (PWM) AC Drives, publication

DRIVES-AT003

Provides basic information on enclosure systems, considerations to help protect against 

environmental contaminants, and power and grounding considerations for installing Pulse 

Width Modulated (PWM) AC drives.

Wiring and Grounding Guidelines for Pulse Width Modulated (PWM) AC Drives, publication 

DRIVES-IN001

Provides basic information to properly wire and ground PWM AC drives.

Product Certifications website

rok.auto/certifications

Provides declarations of conformity, certificates, and other certification details.

Rockwell Automation Knowledgebase

The Rockwell Automation Support Forum

Summary of Contents for PowerFlex 755T

Page 1: ...to installPowerFlex 755Tproducts and familiar withassociated machinery should plan or implement the installation start up and subsequent maintenance of the system Failure to comply can result in perso...

Page 2: ...m 0 25 in Hexagonal socket wrench 11 mm Phillips screwdriver bit 2 Torx star or hexalobular screw driver bit T20 25 30 Torque wrench 1 12 N m 8 8 106 lb in Torque wrench 6 50 N m 53 443 lb in Item Qua...

Page 3: ...me5ConduitBoxInstallation Follow these steps to install the frame 5 conduit box and debris hood 1 Use the pilot holes in the conduit box bottom plate to drill the required holes for control and input...

Page 4: ...July 2019 PowerFlex 755T Frames 5 and 6 Conduit Box with Debris Hood and Ground Plate Kits 2 Loosen the four M4 captive screws that secure the cover to the assembly and remove the cover 4x 2 M4 Capti...

Page 5: ...ighten the four M5 x 10 mm slotted torx screws in the holes on the bottom sides of the chassis to secure the conduit box to the chassis 5 Insert and tighten the two M6 x 12 mm torx screws in the holes...

Page 6: ...to secure the bottom plate to the conduit box 7 Route the control and power cables through the bottom plate of the conduit box and connect them to the appropriate input and output power terminals See...

Page 7: ...6 Conduit Box with Debris Hood and Ground Plate Kits 8 Insert and tighten the M6 x 12 mm torx screw in the hole on the front of the conduit box to secure the front plate to the conduit box 9 Secure t...

Page 8: ...N112A EN P July 2019 PowerFlex 755T Frames 5 and 6 Conduit Box with Debris Hood and Ground Plate Kits 10 Place the debris hood on the top of the chassis and tighten the four M5 captive Phillips head s...

Page 9: ...at No 20 750 CBOX1 F6 The frame 6 conduit box with debris hood kit contains the following components Item Quantity Description 1 1 Conduit box bottom plate with captive screws 2 1 Conduit box with cap...

Page 10: ...conduit box and debris hood 1 Use the pilot holes in the conduit box bottom plate to drill the required holes for control and input output power wire conduit fittings Pilot holes for control power wir...

Page 11: ...ly 2019 11 PowerFlex 755T Frames 5 and 6 Conduit Box with Debris Hood and Ground Plate Kits 2 Loosen the eight M4 captive screws that secure the cover to the assembly and remove the cover 8x 2 M4 Capt...

Page 12: ...the PE ground studs on the chassis 4 Place the two slots in the tab at the top of the conduit box onto the ground studs 5 Align and tighten the four M4 captive slotted torx screws on the conduit box...

Page 13: ...ix M4 captive slotted torx screws to secure the plate to the box 8 Route the power cables through the bottom plate of the conduit box and connect them to the appropriate input and output power termina...

Page 14: ...the two slots at the top of the front cover with the two tabs on the conduit box and place the cover on the box 10 Align and tighten the four M4 captive slotted torx screws on the front plate to secur...

Page 15: ...2A EN P July 2019 15 PowerFlex 755T Frames 5 and 6 Conduit Box with Debris Hood and Ground Plate Kits 12 Place the debris hood on the top of the chassis and tighten the four M4 captive slotted torx sc...

Page 16: ...me 5 ground plate kit contains the following components Item Quantity Description Item Quantity Description 1 1 Ground plate 4 2 M4 x 11 mm ground screws 2 4 M5 x 10 mm slotted torx screws for ground...

Page 17: ...onduit Box with Debris Hood and Ground Plate Kits Frame5GroundPlateInstallation Follow these steps to install the frame 5 ground plate 1 Loosen the four M4 captive screws that secure the cover to the...

Page 18: ...tighten the four M5 x 10 mm torx screws in the holes on the side panels of the chassis to secure the ground plate to the chassis 3 Insert and tighten the two M6 x 12 mm torx screws in the holes on th...

Page 19: ...Plate Kits 4 As required insert the M4 slotted torx screws to secure ground wires to the ground plate 5 As required insert the appropriate sized cable clamps into the ground plate receptacles and secu...

Page 20: ...Ground Plate Kits Frame6GroundPlateKitContents Cat No 20 750 GNDPLT F6 The frame 6 ground plate kit contains the following components Item Quantity Description Item Quantity Description 1 1 Ground pl...

Page 21: ...onduit Box with Debris Hood and Ground Plate Kits Frame6GroundPlateInstallation Follow these steps to install the frame 6 ground plate 1 Loosen the eight M4 captive screws that secure the cover to the...

Page 22: ...hers from the PE ground studs on the chassis 3 Place the two slots in the tab at the top of the ground plate onto the PE ground studs 4 Align and tighten the four M4 captive slotted torx screws on the...

Page 23: ...ORCE ControlTechnical Data publication 750 TD100 Provides detailed information on Drive and bus supply specifications Option specifications Fuse and circuit breaker ratings PowerFlex 750 Series Produc...

Page 24: ...any suggestions on how to improve this document complete the How Are We Doing form at http literature rockwellautomation com idc groups literature documents du ra du002_ en e pdf Technical Support Cen...

Reviews: