12
Rockwell Automation Publication 750-IN112A-EN-P - July 2019
PowerFlex 755T Frames 5 and 6 Conduit Box with Debris Hood and Ground Plate Kits
3. Remove the two M8 nuts and washers from the PE ground studs on the chassis.
4. Place the two slots in the tab at the top of the conduit box onto the ground studs.
5. Align and tighten the four M4 captive slotted-torx screws on the conduit box to secure it to the chassis.
6. Tighten the two M8 nuts and washers on the PE ground studs.
4
5
M4 (Captive)
T20
3.6 N
•
m (32 lb
•
in)
4
5
5
6
M8
13 mm
9.0 N
•
m (80 lb
•
in)
3. Remove Nuts and Washers.