Allen-Bradley PanelView C1000 Installation Instructions Manual Download Page 31

PanelView Component HMI Terminals     

31

Publication 2711C-IN001H-EN-P - July 2014

Power 
consumption, 
max

5 W
(0.21 A @ 24V DC)

7W 
(0.28A @ 24V DC)

10 W
(0.42 A @ 
24V DC)

18 W
(0.75 A @ 
24V DC)

Weight, approx. Function key:

0.19 kg (0.40 lb)
Keypad:
0.30 kg (0.65 lb)

Keypad:
0.30 kg (0.65 lb)
Touch:
0.20 kg (0.43 lb)

Touch:
0.347 kg (0.76 lb)

Touch:
0.68 kg (1.48 lb)

Touch:
1.57 kg 
(3.41 lb)

Dimensions 
(HxWxD), 
approx.

Function key:
80 x 116 x 54 mm 
(3.15 x 4.54 x 
2.13 in.)
Keypad:
119 x 139 x 55 mm 
(4.69 x 5.47 x 
2.15 in.)

Touch:
80 x 116 x 57 mm 
(3.15 x 4.54 x 
2.23 in.)
Keypad:
119 x 139 x 55 mm 
(4.69 x 5.47 x 
2.15 in.)

Touch:
113 x 138 x 43 mm
(4.45 x 5.43 x 
1.69 in.)

Touch:
154 x 209 x 
57 mm 
(6.0 x 8.23 x 
2.25 in.)

Touch:
250 x 308  x 
54 mm (9.84 x 
12.13 x 
2.13 in.)

General Specifications

Attribute

Value

Isolation voltage

For 2711C-T4T only

30V (continuous), Basic Insulation Type
Tested @ 500V for 60 s, line to ethernet 
No isolation between all ports to line, except ethernet port.
Duration indicates that the product was qualification or type tested to the specified level 
(one time tested on a representative sample)

Wire size

Single-Wire Gauge: 0.33…2.08 mm

2

 (22...14 AWG)

Dual-wire Gauge: 0.33…1.31 mm

2

 (22…16 AWG)

Earth wire: 2.08…3.31 mm

2

 (14…12 AWG)

Wire type

Solid or stranded copper wire rated @ 90 °C (194 °F ), or greater

Wiring category

(1)

1 – on power ports
1 – on communication ports

Enclosure type ratings

Meets NEMA/UL Type 4X (indoor) 12, 13, and IEC IP54, IP65 (when marked)
C600 Series B only: NEMA/UL Type 12, 13, and IEC IP54

North American Temp Code

T3C – 

for 2711C-T4T only

(1)

Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, 
publication 

1770-4.1

.

Environmental Specifications

Attribute

Value

Temperature, operating

IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
0…50 °C (32…122 °F)

Temperature, nonoperating

IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),
IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat),
IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock):
-25…70 °C (-13…158 °F)

PanelView Component - 2711C-F2M, 2711C-K2M, 2711C-T3M, 2711C-K3M, 2711C-T6M, 
2711C-T4T, 2711C-T6C, 2711C-T6T, 2711C-T10C

Attribute

Value

C200

C300

C400

C600

C1000

Summary of Contents for PanelView C1000

Page 1: ...es not provide information on how to configure or run applications on the following devices 2711C F2M 2711C K2M 2711C T3M 2711C K3M 2711C T6M 2711C T4T 2711C T6C 2711C T6T 2711C T10C Topic Page Enviro...

Page 2: ...tallation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to...

Page 3: ...specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts The enclosure must have suitable flame retardan...

Page 4: ...faible peut tre utilis pour d terminer le code de temp rature global du syst me Les combinaisons d quipements dans le syst me sont sujettes inspection par les autorit s locales qualifi es au moment d...

Page 5: ...ns against leaks and maintain IP enclosure type requirements ATTENTION This product is intended to be mounted to a well grounded mounting surface such as a metal panel Additional grounding connections...

Page 6: ...lay without having to download first PanelView Component C200 and C300 Terminals Cat No Model Operator Input Size Display Type 2711C F2M C200 Function keys 2 in Monochrome 2711C K2M Numeric and functi...

Page 7: ...485 port 6 USB host Item Description Item Description 1 Touch display function keys 7 24V DC power input 2 Power status LED 1 1 The Power Status LED is red when in screen saver or dimmer mode and gree...

Page 8: ...C600 2711C T6M 2711 T6C Series C or later 2711C T6T Series A or later Item Description Item Description 1 Touch display 7 USB device port 2 24V DC power input 8 Diagnostic status indicator 3 10 100 MB...

Page 9: ...ines Supporting panels must be at least 16 gauge to provide proper sealing against water and dust and to provide proper support The panel surface must be flat and free of imperfections to maintain an...

Page 10: ...52 0 04 99 0 1 0 3 90 0 04 C200 and C300 Keypad C400 Touchscreen and function keys 99 0 1 0 3 90 0 04 119 0 1 0 4 69 0 04 C600 Touch 135 0 1 0 5 31 0 04 189 0 1 0 7 44 0 04 C1000 Touch 231 0 1 0 9 09...

Page 11: ...he enclosure and the gasket is fully compressed You will hear a series of clicks as the clamps self adjust to the panel thickness IMPORTANT The terminal temperature must be greater than 0 C 32 F durin...

Page 12: ...de each lever until the short flat side of the lever touches the surface of the panel 3 When both levers are in place slide each lever an additional notch or two until you hear a click ATTENTION Follo...

Page 13: ...2711C T6M T6C Series C or later 2711C T6T Series A or later only terminal release the mounting lever by rotating it in the direction indicated slide it to the bottom of the mounting slot and remove it...

Page 14: ...elease each panel clamp from its locked position Do this as soon as possible after the removing the terminal from the panel Follow these steps to unlock each panel clamp 1 Insert the tip of a flat bla...

Page 15: ...teps to mount the terminal in a panel ATTENTION Follow these guidelines when mounting the terminal in a panel Disconnect all electrical power from the panel before making the panel cutout Make sure th...

Page 16: ...el cutout 4 Insert all mounting levers into the mounting slots on the terminal Slide each lever until the short flat side of lever touches the surface of the panel 5 When all levers are in place slide...

Page 17: ...gs for Alignment Lever Position Panel Thickness Range Typical Gauge 1 1 52 2 01 mm 0 060 0 079 in 16 2 2 03 2 64 mm 0 08 0 104 in 14 3 2 67 3 15 mm 0 105 0 124 in 12 4 3 17 3 66 mm 0 125 0 144 in 10 5...

Page 18: ...nt C200 and C300 Dimensions PanelView Component Height Approx Width Approx Overall Depth Approx Mounted Depth Approx a b c d C200 Keypad C300 Keypad 119 mm 4 69 in 139 mm 5 47 in 55 mm 2 15 in 49 mm 1...

Page 19: ...anelView Component HMI Terminals 19 Publication 2711C IN001H EN P July 2014 PanelView Component C400 Touch Terminals PanelView Component C600 Touch Terminals a b c d 45850 PanelView C600 a b c d 44884...

Page 20: ...same ground system connect to the USB peripheral through a galvanically isolated hub PanelView Component C600 C1000 and C400 Dimensions PanelView Component Height Approx Width Approx Overall Depth App...

Page 21: ...not use the USB port in hazardous locations ATTENTION Use a Class 2 Safety Extra low Voltage SELV or Protective Extra low Voltage PELV power supply as required by local wiring codes for your installat...

Page 22: ...ports SELV or PELV power supply Other equipment can share this power supply with the PanelView Component device provided that no ground loops are created A PELV power source internally connects the ne...

Page 23: ...t devices connect to a 24V DC power source The table shows the power ratings for each device The internal nonisolated power supply is protected against reverse polarity of the DC and DC connections Po...

Page 24: ...or disconnect wiring while the power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous befor...

Page 25: ...ION The functional earth connection to ground is mandatory This connection is required for noise immunity reliability and Electromagnetic Compliance EMC with the European Union EU EMC directive for CE...

Page 26: ...r This value is compatible with RS422 and RS485 electrical specifications Additional termination on the PanelView Component end of communication cables is not required Troubleshooting If your terminal...

Page 27: ...g the life of the product The battery provides battery backup for the real time clock It is not used for application backup or retention Fault Indicator States During Startup Fault Red Indicator State...

Page 28: ...y in a fire or incinerator Dispose of used batteries in accordance with local regulations WARNING When you connect or disconnect the battery an electrical arc can occur This could cause an explosion i...

Page 29: ...e battery cover and replace the battery Battery Cover Battery 44888 This equipment is sensitive to electrostatic discharge ESD Follow ESD prevention guidelines when handling this equipment C600 C1000...

Page 30: ...matrix LCD Display size 2 in 3 in 4 in 5 7 in 10 4 in Display area 49 x 14 mm 1 93 x 0 55 in 67 x 33 mm 2 64 x 1 30 in 95 04 x 53 86 mm 3 74 X 2 12 in 115 x 86 mm 4 53 x 3 39 in 211 x 158 mm 8 31 x 6...

Page 31: ...time tested on a representative sample Wire size Single Wire Gauge 0 33 2 08 mm2 22 14 AWG Dual wire Gauge 0 33 1 31 mm2 22 16 AWG Earth wire 2 08 3 31 mm2 14 12 AWG Wire type Solid or stranded coppe...

Page 32: ...1 kHz sine wave 80 AM from 1400 2000 MHz 1V m with 1 kHz sine wave 80 AM from 2000 2700 MHz EFT B Immunity IEC 61000 4 4 2 kV 5 kHz on power ports 1 kV 5 kHz on communication ports Surge Transient Imm...

Page 33: ...on distributor or sales representative EAC Russian Customs Union TR CU 020 2011 EMC Technical Regulation RCM Australian Radiocommunications Act compliant with AS NZS CISPR 11 Industrial Emissions KC K...

Page 34: ...34 PanelView Component HMI Terminals Publication 2711C IN001H EN P July 2014 Notes...

Page 35: ...PanelView Component HMI Terminals 35 Publication 2711C IN001H EN P July 2014 Notes...

Page 36: ...information that s contained in this manual You can also contact a special Customer Support number for initial help in getting your product up and running New Product Satisfaction Return Rockwell Auto...

Reviews: