Publication 1794-RM001G-EN-P - December 2011
SIL Policy
1-9
1794-OB8EP
Protected Output Module
2,389,669
(2)
4.18E-07
7.54E-06
1794-OE4
Analog Output Module
23,807,086
4.20E-08
7.41E-07
1794-OF4I
Isolated Analog Output Module
7,191,128
1.39E-07
2.47E-06
1794-OW8
Relay Output Module
14,766,876
6.77E-08
1.20E-06
1794-TB3
Terminal Base Units
21,128,346
4.73E-08
8.35E-07
1794-TB3G
Generic Terminal Base Units
27,320,800
3.66E-08
6.45E-07
1794-TB3GS
Generic Terminal Base Units
46,425,600
2.15E-08
3.79E-07
1794-TB3S
Terminal Base Unit
71,433,747
1.40E-08
2.46E-07
1794-TB3T
Temperature Terminal Base Units
73,096,226
1.37E-08
2.41E-07
1794-TB3TS
Temperature Terminal Base Units
75,763,399
1.32E-08
2.32E-07
1794-TBN
Terminal Base Units
75,716,615
1.32E-08
2.32E-07
1794-TBNF
Fused Terminal Base Units
4,812,320
2.08E-07
3.70E-06
1794-ACNR15XT
ControlNet Redundant Media Adapter
8,223,684
1.22E-07
2.15E-06
1794-AENTRXT
10/100Mb Ethernet Redundant Communication Adapter
1,268,070
7.89E-07
1.45E-05
1794-OB8EPXT
8 Protected Output Module
14,771,049
6.77E-08
1.20E-06
1794-IB16XT
16 Sink Input Module
35,587,189
2.81E-08
4.95E-07
1794-OB16PXT
16 Protected Output Module
26,709,401
3.74E-08
6.60E-07
1794-IB10XOB6XT
10 Input/6 Output Combo Module
22,202,487
4.50E-08
7.94E-07
1794-OW8XT
8 Relay Output Module
18,518,519
5.40E-08
9.53E-07
1794-IE4XOE2XT
4 Input/2 Output Analog Combo Module
11,800,802
8.47E-08
1.50E-06
1794-IE8XT
8 Input analog Module
14,041,000
7.12E-08
1.26E-06
1794-OE4XT
4 Output Analog Module
11,381,744
8.79E-08
1.55E-06
1794-IF2XOF2IXT
2 Input/2 Output Isolated Analog Combo Module
6,317,918
1.58E-07
2.81E-06
1794-IF4IXT
4 Isolated Input Analog Module
7,297,140
1.37E-07
2.43E-06
1794-IF4ICFXT
4 Isolated Input Analog Module
7,297,140
1.37E-07
2.43E-06
1794-OF4IXT
4 Isolated Output Analog Module
5,493,902
1.82E-07
3.24E-06
1794-IJ2XT
2 Ch. Frequency Counter Module
11,714,128
8.54E-08
1.51E-06
1794-IRT8XT
8 TC/RTD Input Analog Module
8,204,792
1.22E-07
2.16E-06
(1)
MTBF measured in hours.
(2)
Calculated using field-based values for components
(3)
λ
= Failure Rate = 1/MTBF
Table 1.2 FLEX I/O Product Probability of Failure on Demand (PFD) Calculations (T
1
= 1
yr
)
Catalog Number
Description
Mean Time
Between Failure
(MTBF)
(1)
λ
(3)
Calculated PFD
1oo2 architecture
Summary of Contents for FlexLogix 1794
Page 1: ...FLEXI OSystemwithControlLogixforSIL2 Catalog Number Bulletin 1794 Reference Manual AB Drives ...
Page 18: ...Publication 1794 RM001G EN P December 2011 1 14 SIL Policy Notes ...
Page 22: ...Publication 1794 RM001G EN P December 2011 2 4 ControlLogix Communications ...
Page 42: ...Publication 1794 RM001G EN P December 2011 3 20 FLEX I O Modules Notes ...
Page 56: ...Publication 1794 RM001G EN P December 2011 A 10 Failure Estimates Notes ...
Page 59: ...AB Drives ...