Allen-Bradley ControlLogix DeviceNet Installation Instructions Manual Download Page 3

Rockwell Automation Publication 1756-IN065A-EN-P - September 2017

3

ControlLogix DeviceNet Scanner Module

North American Hazardous Location Approval

The following information applies when operating this equipment in hazardous 
locations.

Informations sur l’utilisation de cet équipement en environnements dangereux.

Products marked "CL I, DIV 2, GP A, B, C, D" are suitable for use in Class I Division 2 Groups A, B, C, 
D, Hazardous Locations and nonhazardous locations only. Each product is supplied with 
markings on the rating nameplate indicating the hazardous location temperature code. When 
combining products within a system, the most adverse temperature code (lowest "T" number) 
may be used to help determine the overall temperature code of the system. Combinations of 
equipment in your system are subject to investigation by the local Authority Having Jurisdiction 
at the time of installation.

Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne conviennent qu'à une utilisation en 
environnements de Classe I Division 2 Groupes A, B, C, D dangereux et non dangereux. Chaque 
produit est livré avec des marquages sur sa plaque d'identification qui indiquent le code de 
température pour les environnements dangereux. Lorsque plusieurs produits sont combinés dans un 
système, le code de température le plus défavorable (code de température le plus faible) peut être 
utilisé pour déterminer le code de température global du système. Les combinaisons d'équipements 
dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de 
l'installation.

WARNING:
Explosion Hazard –

• Do not disconnect equipment unless power has been removed or the 

area is known to be nonhazardous. 

• Do not disconnect connections to this equipment unless power has 

been removed or the area is known to be nonhazardous. Secure any 
external connections that mate to this equipment by using screws, 
sliding latches, threaded connectors, or other means provided with this 
product.

• Substitution of components may impair suitability for Class I, Division 2.
• If this product contains batteries, they must only be changed in an area 

known to be nonhazardous.

AVERTISSEMENT:
Risque d’Explosion – 

• Couper le courant ou s'assurer que l'environnement est classé non 

dangereux avant de débrancher l'équipement.

• Couper le courant ou s'assurer que l'environnement est classé non 

dangereux avant de débrancher les connecteurs. Fixer tous les connecteurs 
externes reliés à cet équipement à l'aide de vis, loquets coulissants, 
connecteurs filetés ou autres moyens fournis avec ce produit.

• La substitution de composants peut rendre cet équipement inadapté à une 

utilisation en environnement de Classe I, Division 2.

• S'assurer que l'environnement est classé non dangereux avant de changer 

les piles.

European Hazardous Location Approval

The following applies to products marked 

 II 3 G:

Are Equipment Group II, Equipment Category 3, and comply with the Essential Health and Safety Requirements relating to the design and construction of such 
equipment given in Annex II to Directive 2014/34/EU. See the EC Declaration of Conformity at http://www.rockwellautomation.com/products/certification for details.

The type of protection is "Ex nA IIC T4 Gc" according to EN 60079-15.

Comply to Standards EN 60079-0:2012, EN 60079-15:2010, reference certificate number LCIE01ATEX6020X.

Are intended for use in areas in which explosive atmospheres caused by gases, vapors, mists, or air are unlikely to occur, or are likely to occur only infrequently and for 
short periods. Such locations correspond to Zone 2 classification according to ATEX directive 2014/34/EU.

May have catalog numbers followed by a "K" to indicate a conformal coating option.

ATTENTION: 

• Installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in 

accordance with applicable code of practice.

• In case of malfunction or damage, no attempts at repair should be made. The module should be returned to the manufacturer for repair. Do not dismantle 

the module.

• This equipment is certified for use only within the surrounding air temperature range of 0…60 °C (32…140 °F). The equipment must not be used outside 

of this range.

• Use only a soft dry anti-static cloth to wipe down equipment. Do not use any cleaning agents.

IMPORTANT

Any illustrations, charts, sample programs, and layout examples that are shown in this publication are intended solely for the purposes of example. Since there 
are many variables and requirements that are associated with any particular installation, Rockwell Automation does not assume responsibility or liability for 
actual use based on the examples shown in this publication.

Electrical Safety Consideration

ATTENTION: 

Power to the DeviceNet network must be supplied from a source compliant with the following as appropriate for the intended application:

• Class 2 approved to UL1310
• Limited Voltage Limited Current Supply compliant with UL508
• SELV source approved to EN/IEC60950-1, EN/IEC61010-2-201 or EN/IEC62368-1 (ES1) 
• PELV source approved to EN/IEC60950-1, EN/IEC61010-2-201 or EN/IEC62368-1 (ES1)
• Isolation from Mains power via an approved Isolating Transformer constructed with Reinforced Insulation, Basic plus a Supplementary Insulation, or Basic 

insulation with a protective screen.

Summary of Contents for ControlLogix DeviceNet

Page 1: ...756 DNB 1756 DNBK ControlLogix DeviceNet scanners are devices that are used with various programmable controllers on the DeviceNet network Topic Page About the Module 5 Determine Module Slot Location 5 Change Module Settings 5 Install the Module in the Chassis 7 Specifications 9 Additional Resources 10 ...

Page 2: ...code de pratique en vigueur Si cet équipement est utilisé d une façon qui n a pas été définie par le fabricant la protection fournie par l équipement peut être compromise 주의 본 제품 설치 설정 작동 또는 유지 보수하기 전에 본 문서를 포함하여 설치 설정 및 작동에 관한 참고 자료 섹션의 문서들을 반드시 읽고 숙지하 십시오 사용자는 모든 관련 규정 법규 및 표준에서 요구하는 사항에 대해 반드시 설치 및 배선 지침을 숙지해야 합니다 설치 조정 가동 사용 조립 분해 유지보수 등 모든 작업은 관련 규정에 따라 적절한 교육을 받은 사용자를 통해서만 수행해야 합니다 본 장비를 제조사...

Page 3: ...itution de composants peut rendre cet équipement inadapté à une utilisation en environnement de Classe I Division 2 S assurer que l environnement est classé non dangereux avant de changer les piles European Hazardous Location Approval The following applies to products marked II 3 G Are Equipment Group II Equipment Category 3 and comply withthe Essential Health and Safety Requirements relating to t...

Page 4: ...that can affect module operation Waste Electrical and Electronic Equipment WEEE Attheendofitslife thisequipmentshouldbecollectedseparatelyfromany unsorted municipal waste Prevent Electrostatic Discharge ATTENTION Thisequipmentissensitivetoelectrostaticdischarge which can cause internal damage and affect normal operation Follow these guidelines when you handle this equipment Touch a grounded object...

Page 5: ...ng in a 4 slot chassis Slot 0 is the first slot and is always the leftmost slot in the chassis ChangeModuleSettings The module ships with these settings Factory Setting Values Factory Settings Value Rotary switches 999 Communication data rate Software settable default 125 Kbps Node address Software settable default 63 31713 M Front View Side View Top View Backplane Connector USB Port Front Panel D...

Page 6: ...1756 DNB scanner 2 Select Tools and Node Commissioning 3 Browse to the DeviceNet network for the 1756 DNB scanner you want to commission 4 Select the 1756 DNB scanner you want to commission 5 In the Data Rate field select the communication data rate 6 Click Apply 7 Cycle power to the 1756 DNB scanner SettheNodeAddress The 1756 DNB scanner supports DeviceNet node addresses 00 63 The factory default...

Page 7: ...ctory default communication rate and node address 1 Set the switches to 888 2 Restore power to the module When the out of box reset is complete the alphanumeric display repeatedly scrolls the message Reset Complete Change Switch Settings During this time the module does not respond to communication from any port including the backplane DeviceNet connector or USB port 3 After the module resets perf...

Page 8: ...ector to the module DeviceNet port as shown Tighten the screws on the connector as needed IMPORTANT For detailed DeviceNet connection information see the DeviceNet Media Design and Installation Guide publication DNET UM072 Also see the Industrial Automation Wiring and Grounding Guidelines publication 1770 2 1 Color Chips dots Red Dot Black Dot Blue Dot White Dot 10 position Plug 5 position Plug 20...

Page 9: ...Shock 0 C Ta 60 C 32 F Ta 140 F Temperature surrounding air max 60 C 140 F Voltage and current ratings Backplane 5 1V DC 400 mA DeviceNet Power 60 mA 11 2V DC CL 2 SELV limited to 100VA Isolation voltage 50V continuous Basic Insulation Type DeviceNet to Backplane No isolation between USB and Backplane Type tested at 860V AC for 60 s Terminal block torque specs DeviceNet connector 0 56 0 79 N m 5 7...

Page 10: ...deos FAQs Chat User Forums and Product Notification Updates https rockwellautomation custhelp com Local Technical Support Phone Numbers Locate the phone number for your country http www rockwellautomation com global support get support now page Direct Dial Codes Find the Direct Dial Code for your product Use the code to route your call directly to a technical support engineer http www rockwellauto...