Publication 1756-UM001G-EN-P - January 2007
Develop Motion Applications
93
Add SERCOS Interface
Drives
With the addition of SERCOS interface modules to a controller’s I/O
configuration, you can use RSLogix 5000 programming software to set
up the modules.
To add SERCOS interface modules, perform this procedure.
1.
In the I/O configuration tree in RSLogix 5000 programming
software, right-click the SERCOS network and select New
Module.
The Select Module dialog appears.
2.
Double-click Other.
3.
Select your drive.
Choose from these SERCOS interface drives:
•
1394
•
Kinetix 6000
•
Ultra3000
•
8720MC
4.
Click OK.