Types of Sealing 

Parallel Thread

Tapered Thread (NPT)

Correct sealing of the process connections with parallel threads at the sealing face must be made using suitable flat gaskets and sealing rings.

The sealing of the tapered threads (for example, NPT thread) is made by providing the thread with additional sealing material such as, PTFE tape 

(EN 837-2).

Dismounting and Disposal

Dismounting:

 Only disconnect the pressure transmitter once the system has been depressurized. 

Disposal

: Incorrect disposal can put the environment at risk. 

Dispose of instrument and packaging materials in an environmentally compatible way and in accordance with the country-specific waste disposal 

regulations. 

Rockwell Automation Support

For technical support, visit 

http://www.rockwellautomation.com/support/overview.page

.

Waste Electrical and Electronic Equipment (WEEE)

ATTENTION: 

Residual media in the dismounted pressure transmitter can result in a risk to persons, the environment, and equipment. Take sufficient 

precautionary measures.

At the end of life, this equipment should be collected separately 
from any unsorted municipal waste.

per EN 837

per DIN 3852-E

NPT

Summary of Contents for 836P-N2 Series

Page 1: ...equired for installation and commissioning Failure to comply results in personal injury or equipment damage During mounting make sure that the sealing faces at the instrument and the measuring point are clean and undamaged Safety Installation Considerations Before installation commissioning and operation be sure that the appropriate pressure transmitter has been selected in terms of measuring rang...

Page 2: ... in Hg 100 30 in Hg 145 30inHg 200 30 in Hg 250 30 in Hg 300 Overpressure Limit 29 40 60 72 120 200 290 400 500 600 Performance Characteristics Reference Operation Conditions per IEC 61298 1 Operating Conditions Environment Load Analog signal 4 20 mA Power supply 8V 0 02 A Temperature 15 25 C 59 77 F Ambienttemperature range 1 4 in NPT 30 100 C 22 212 F G 1 4 in 30 100 C 22 212 F G 1 2 in 30 100 C...

Page 3: ...ingCables ProcessConnection 889D F4AC 2 M12x1 connector Measuring Cell Piezoresistive measuring cell and metallic measuring diaphragm 889D R4AC 2 M12x1 right angle connector Application Measurement and monitoring of absolute and gauge pressures Process connection Thread 1 4 NPT female 1 4 NPT male G1 4 BSPP male G 1 2B SAE 7 16 20 UNF O ring BOSS ATTENTION Before commissioning the pressure transmi...

Page 4: ...llel threads at the sealing face must be made using suitable flat gaskets and sealing rings The sealing of the tapered threads for example NPT thread is made by providing the thread with additional sealing material such as PTFE tape EN 837 2 DismountingandDisposal Dismounting Only disconnect the pressure transmitter once the system has been depressurized Disposal Incorrect disposal can put the env...

Reviews: