22
Industrial Integrated Display Computers
Rockwell Automation Publication 6181P-IN010D-EN-P - April 2012
Environmental Specifications
Attribute
Value
Temperature, operating
(1)
All Standard models
1200P Non-display
1200P and 1500P Performance
1700P Performance
0…50 °C (32…122 °F)
0…55 °C (32…131 °F)
0…55 °C (32…131 °F)
0…50 °C (32…122 °F)
Temperature, nonoperating
-20…60 °C (-4…140 °F)
Relative humidity
10…90% noncondensing
Altitude, operating
2,000 m (6,561 ft)
Altitude, nonoperating
12,000 m (40,000 ft)
Shock, operating
(2)(3)
15 g (1/2 sine, 11 ms)
Shock, nonoperating
30 g (1/2 sine, 11 ms)
Vibration, operating
(3)
6181P
(2)
6181F
(2)
0.006 in. p-p, (10…57 Hz); 1 g peak, (57…640 Hz)
0.012 in. p-p, (10…57 Hz); 2 g peak, (57…640 Hz)
Vibration, nonoperating
0.012 in. p-p, (10…57 Hz); 2 g peak, (57…640 Hz)
(1)
The optical disc drive is considered a maintenance device. Therefore, do not operate computers with an optical disk drive in temperatures above
45 °C (113 °F).
(2)
Applies to panel mounted computers only.
(3)
The optical disc drive is considered a maintenance device. Do not operate computers with this drive in environments with the shock and vibration
levels listed. Do not operate the drive in temperatures above 45 °C (113 °F).
Certifications
(1)
Attribute
Value
c-UL-us
UL/c-UL Listed per UL 60950-1 and CSA C22.2 No. 60950-1-03
CE
Marked for all applicable directives
EMC 2004/108/EC
LVD 2006/95/EC
RoHS
China RoHS
C-Tick
Australian Radiocommunications Act, compliant with:
AS/NZS CISPR 11; Industrial Emissions
(1)
See
http://www.rockwellautomation.com/products/certification/
for declarations of conformity, certificates, and other certification details.