Chapter 5
Issuing BlockTransfer Commands
5-7
Table 5.B
Host BT Read Error Conditions
Error Mnemonic
Code
Description
SUCCESS
0
The BT Read was successful. Read data is included in confirmation.
BAD_COMMAND_DATA_LENGTH
26
Command data length is not 3.
BT_BAD_ADDRESS
27
Logical rack address or slot address is out of range.
BT_BAD_ADDRESS_NOT_IN_SCAN_LIST
28
BT address is not in scan list.
BT_BAD_DATA_LENGTH
29
More than 63 words were specified.
TOO_MANY_REQUESTS_FOR_MODULE
30
This module already has a BT in progress.
BT_QUEUE_FULL
31
Already 64 BT requests pending.
BT_REQUEST_TIMEOUT
36
BT exchange between scanner and adapter did not complete within 4 seconds.
USER_MODULE_REQUEST_TYPE_MISMATCH
38
Host requested a read, module responded with a write request.
USER_MODULE_LENGTH_MISMATCH
39
Length mismatch between what the host requested and the adapter requested.
BT_CHECKSUM_ERROR
41
Checksum error detected in reply packet. BT data invalidated.
instructs the scanner to perform a