Allen-Bradley 1771-IB Installation Data Download Page 6

Specifications

DC (12-24V) Input Module

Cat. No. 1771-IB

Installation Data

 6

Inputs per Module

8

Module Location

1771 I/O chassis

Input Voltage Range

10 to 27V dc

Nominal Input Current

8mA at 12V dc

24mA at 24V dc

Maximum Off-state Current

3.0mA

Maximum Off-state Voltage

7.0V dc

Minimum On-state Voltage

10V dc

Input Impedance

1 to 2K ohms maximum (on-state)

2 to 3K ohms maximum (off-state)

Input Signal Delay

Low to high propagation delay 12ms +7ms

High to low propagation delay 20ms +7ms

Power Dissipation

5.7 Watts (max.), 0.4 Watts (min.)

Thermal Dissipation

19.3 BTU/hr (max.), 1.4 BTU/hr (min.)

Backplane Current

74mA @ 5V dc  +5%

Opto-electrical Isolation

1500V ac rms

Environmental Conditions

Operational Temperature

Storage Temperature

Relative Humidity

0

o

 to 60

o

C (32

o

 to 140

o

F)

-40

o

 to 85

o

C (-40

o

 to 185

o

F)

5 to 95% (without condensation)

Conductors

Wire Size

Category

14 gage stranded maximum

3/64 inch insulation maximum

2

1

Keying

Between 4 and 6

Between 14 and 16

Field Wiring Arm

Catalog Number 1771-WA

1

 

Refer to publication 1770-4.1, Programmable Controller Wiring and Grounding Guidelines.

With offices in major cities worldwide

WORLD
HEADQUARTERS
Allen-Bradley
1201 South Second Street
Milwaukee, WI 53204 USA
Tel: (1) 414 382-2000
Telex: 43 11 016
FAX: (1) 414 382-4444

EUROPE/MIDDLE
EAST/AFRICA
HEADQUARTERS
Allen-Bradley Europe B.V.
Amsterdamseweg 15
1422 AC Uithoorn
The Netherlands
Tel: (31) 2975/43500
Telex: (844) 18042
FAX: (31) 2975/60222

ASIA/PACIFIC
HEADQUARTERS
Allen-Bradley (Hong Kong)
Limited
Room 1006, Block B, Sea
View Estate
28 Watson Road
Hong Kong
Tel: (852) 887-4788
Telex: (780) 64347
FAX: (852) 510-9436

CANADA
HEADQUARTERS
Allen-Bradley Canada
Limited
135 Dundas Street
Cambridge, Ontario N1R
5X1
Canada
Tel: (1) 519 623-1810
FAX: (1) 519 623-8930

LATIN AMERICA
HEADQUARTERS
Allen-Bradley
1201 South Second Street
Milwaukee, WI 53204 USA
Tel: (1) 414 382-2000
Telex: 43 11 016
FAX: (1) 414 382-2400

As a subsidiary of Rockwell International, one of the world’s largest technology
companies — Allen-Bradley meets today’s challenges of industrial automation with over
85 years of practical plant-floor experience. More than 11,000 employees throughout the
world design, manufacture and apply a wide range of control and automation products
and supporting services to help our customers continuously improve quality, productivity
and time to market. These products and  services not only control individual machines but
integrate the manufacturing process, while providing access to vital plant floor data that
can be used to support decision-making throughout the enterprise.

Publication 1771–2.4 – May 1990

Supersedes publication 1771–2.4 – January 1986 and 1771–2.4–DU1 – October 1987

PN 955107–15

Copyright 1991 Allen-Bradley Company, Inc.   Printed in USA

Summary of Contents for 1771-IB

Page 1: ...kage current of your 3 wire devices should not exceed 3mA This module contains input filtering to limit the effect of voltage transients caused by contact bounce and or radiated electrical noise The delay due to input filtering is nominally 12 7ms for turning inputs on and 20 7ms for turning inputs off Your module receives its power through the 1771 I O chassis backplane from the chassis power sup...

Page 2: ...ee work station When not in use keep the module in a static shielded bag In this section we tell you how to key your I O chassis install your module and make your wiring connections Keying Your I O Chassis Use the plastic keying bands shipped with each I O chassis to key the I O slots to accept only this type of module The module circuit board is slotted in two places on the rear edge The position...

Page 3: ... the slot that guide the module into position 3 Do not force the module into its backplane connector Apply firm even pressure on the module to seat it properly 4 Snap the chassis latch over the top of the module to secure its position 5 Connect the wiring arm to the module 6 Make wiring connections to the field wiring arm as indicated in Figures 1 and 2 Connecting Wiring to the Input Module Connec...

Page 4: ...as Allen Bradley proximity switches Bulletin 871 to operate in a current source mode Figure 2 Connect terminal B to the dc common Terminal A is not used Connect the dc line to the other terminal of your input devices Use stranded 14 or 16 gauge wire to minimize the voltage drop over long cable distances Important You can directly drive terminals on an DC 12 24V Input Module cat no 1771 IB from ter...

Page 5: ...ction 11834 I The front panel of your module contains 8 red status LED indicators figure 3 The red status indicators are provided for system logic side indication of individual inputs When a red LED lights voltage is present on the terminal The module transfers this information to the backplane for the processor to read Figure 3 Status Indicators Not used Input 0 Input 1 Input 2 Input 3 Input 4 In...

Page 6: ...PE MIDDLE EAST AFRICA HEADQUARTERS Allen Bradley Europe B V Amsterdamseweg 15 1422 AC Uithoorn The Netherlands Tel 31 2975 43500 Telex 844 18042 FAX 31 2975 60222 ASIA PACIFIC HEADQUARTERS Allen Bradley Hong Kong Limited Room 1006 Block B Sea View Estate 28 Watson Road Hong Kong Tel 852 887 4788 Telex 780 64347 FAX 852 510 9436 CANADA HEADQUARTERS Allen Bradley Canada Limited 135 Dundas Street Cam...

Reviews: