ASCII Module
PLC-2 Family Processors
Appendix A
A50
This program allows you to display two messages files on demand
(NO TAG). One message file contains a message variable (timer
accumulated value). When you enter the word GO from the keyboard of
the peripheral device, your program starts a five–second write block
transfer one–shot routine that transfers message files 1 and 2 to the
peripheral device.
When the string of data containing GO is transmitted to the ASCII
module’s input buffer, the module sets the new data flag (SW2>0), and
transfers data and the new data flag to the processor data table.
Figure A.21
Example Application Program
O0252
07
B0020
02
MOV
MOVE FROM A TO R
A : WB000:0327
0000000000000000
R : WO000:0200
0000000000000000
RUNG NUMBER RM0
Zero out CW1 on power-up
U
RUNG NUMBER RM1
Power-up initialization rung
O0200
07
RUNG NUMBER RM2
O0252
07
B0020
10
B0020
RUNG NUMBER RM3
TON
TIMER ON
1.0 SECOND
TP =
TA =
T0001
2
0
T0001
17
TE
T0001
15
TD
10
T0001
15
B0020
10
RUNG NUMBER RM4
Initialize for 2 seconds
L
Example Application Read/Write
Program