background image

Summary of Contents for 1770-T1

Page 1: ...erutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In st...

Page 2: ...ALLEN BRADLEY 1770 805 Bulletin 1770 Industrial Terminal Systems Cat No 1770 T1 T2 T3 T4 User s Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 3: ...mples shown in this manual are intended solely to illustrate the text of this manual Because of the many variables and requirements associ ated with any particular installation Allen Bradley Company c...

Page 4: ...g a PLC 3 Processor Connecting a Series 7100 CNC Connecting an ASCII Terminal Using Channel B Connecting RS 232 C Devices to Channel 8 Connecting a PLC Processor for Report Generation Connecting a PLC...

Page 5: ...0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 e 0 0 0 0 0 0 0 0 e 0 0 Industrial Terminal Keyboard 0 Keytop Overlays a o o eo o o o o o o o o o o o o o o o o o o o eo o o eo o o o o o o o o o Protective C...

Page 6: ...ions Menu 1770 T1 T2 and T3 6 2 6 3 Graphics Example 6 6 Section Paragraph LIST OF TABLES Title Page 1 1 Supporting Documentation 1 1 1 2 Industrial Terminal Systems 1 2 1 3 Industrial Terminal Proces...

Page 7: ...ayed on the CRT screen 1 2 DESCRIPTION There are four Industrial Terminal Systems Cat No 1770 T1 T2 T3 and T4 available Each has the same types of equipment These items include Industrial Terminal CRT...

Page 8: ...ystem Cat No 0 Modules Keytop Overlays 1770 T1 PLC 2 Keyboard PLC 2 Keytop Overlay Cat No 1770 FC Cat No 1770 KCA Alphanumeric Keytop Overlay Cat No 1770 KAA 1770 T2 PLC PLC 2 Keyboard PLC Keytop Over...

Page 9: ...2 15 Processors Therefore programs entered on these Pro cessors using a 1770 T3 Industrial Terminal System must not be edited using either 1770 T1 or T2 Industrial Terminal Systems The limitations foo...

Page 10: ...instruction single multiple word or block determine the num ber of rungs or rung branches and the number of elements per rung displayed on the screen 2 1 CRT The Industrial Terminal System has a nine...

Page 11: ...Black White CRT monitor capable of underscan operation The function of each channel and the cables required are described in Table 2 1 2 4 KEYBOARD CONNECTOR COVER The Industrial Terminal System is s...

Page 12: ...ustrial Terminal Keyboard Page 2 3 1770 805 sors Both the keytop overlays that are shipped with each Industrial Terminal System and the optional keytop overlays are identified in Figure 2 3 2 6 PROTEC...

Page 13: ...eric Keytop Overlay 0 f D JOOOOOOOOOOODD BBBBBBBEJBCDliJOO BBBBEJBBBEJ fiJ J J O JOJCOBBBBBBBGJ J OEJEJEJBBBBBBBl J PLC 2 Keytop Overlay 0 f PLC 3 Keytop Overlay 9 D Part of a 1770 T1 System 6 Part of...

Page 14: ...is Figure 3 1 and insert the keyboard 5 Lift and move the locking lever to the LOCK position Note that the PLC 2 Family Keyboard Cat No 1770 FD and the PLC 3 Keyboard Cat No 1770 FE have a projection...

Page 15: ...ositioning the AC selector board located on the back of the Industrial Terminal CRT Monitor Figure 3 4 The board has four positions 100 120 220 and 240 When either 100 or 120 is selected the voltage r...

Page 16: ...ith the power switch OFF disconnect the AC power cord from the Industrial Terminal CRT Monitor 2 Slide the plastic cover to the left over the AC power cord connection 3 Pull the FUSE PULL lever to the...

Page 17: ...DOWN DOWN 4800 UP DOWN UP 9600 UP UP DOWN NOT USED UP UP UP 0 When connecting to a PLC Processor this switch setting must be used fJ With a 1770 T3 system this setting can be used for Automatic Report...

Page 18: ...et X _Bj Labeled Interface 0 r y I or Program Panel E J D AG OSTICS c nected from the PLC 2 Family Processor without removing AC power 4 2 CONNECTING A PLC PROCESSOR Note Before making any connections...

Page 19: ...either Channel 0 on the front panel or Channel 5 on the 1 0 Scanner Programmer Interface Module Cat No 1775 S4A inside the PLC 3 Chassis The 1770 T4 Industrial Terminal System can be connected up to 5...

Page 20: ...ector 10058 FIGURE 4 4 PLC Remote Cable Diagram connecting and disconnecting the Industrial Terminal System 4 5 CONNECTING AS AN ASCII TERMINAL USING CHANNEL B The Industrial Terminal System can opera...

Page 21: ...minal Cable Cat No 1775 CAT FIGURE 4 5 PLC 3 Connection Diagram Programming Front Panel or 1775 84A Module Report Generation 1775 848 Module 1770 T4 Industrial Terminal 0_ i Channel B Up to 5000 Cable...

Page 22: ...ote Cable Diagram Series 7100 CNC 1770 T1 T2 or T3 Industrial Terminal PI Module Program Panel Interconnect Cable Cat No 1772 TC Channel A FIGURE 4 8 Industrial Terminal Series 7100 CNC PI Connection...

Page 23: ...B Figure 4 9 identifies the pins used The cable to be used is Cat No 1778 CR Belden 8723 or its equiva lent and is constructed as shown in Figure 4 10 The parts for constructing this cable are listed...

Page 24: ...FIGURE 4 11 Data Handling Connection Diagram 13 feet cable is constructed as shown in Figure 4 13 using two male connectors The parts needed to construct the cable are listed in Table 4 1 4 5 3 Conne...

Page 25: ...ct the PLC 3 Processor up to 5000 feet from the Industrial Terminal System for report generation Figure 4 6 a cable with two male connectors must be constructed using Cat No 1778 CR Belden 8723 or equ...

Page 26: ...le Cat No 1774 DC2 FIGURE 4 13 PLC Remote Report Generation Cable Diagram Protective Ground Received Channel C Data 2 3 Transmitted Data 6 Data Set j j Ready 1 Signal Ground j Carrier Detect FIGURE 4...

Page 27: ...ction 3 6 must match the baud rate and parity of the data received on Channel B 5 2 MODE SELECTION WITH A T1 T2 OR T3 SYSTEM The operating modes for the 1770 T1 T2 and T3 systems are selected in the s...

Page 28: ...re determined by the switch group settings on the Industrial Ter minal System If the switches are in the NOT USED position both up the Industrial Ter minal System tries to communicate with a PLC 3 Pro...

Page 29: ...1770 FEC SERIES A A 1 PLC 3 MODE 2 ALPHANUMERIC MODE SELECT MODE NUMBER 1770 T4 FIGURE 5 3 Mode Selection Menu T4 10070 Page 5 3 1770 805 Artisan Technology Group Quality Instrumentation Guaranteed 8...

Page 30: ...its transmitted per second The number initially displayed reflects the switch group assembly setting When the 110 baud rate is selected two stop bits are used With all other baud rates one stop bit is...

Page 31: ...NGED AND OR PRESS RETURN TO SET OPTIONS AS DISPLAYED Reflects Current Settings of the Switch Group Assembly 10071 FIGURE 6 2 Alphanumeric Options Menu 1770 T1 T2 and T3 ALPHANUMERIC TERMINAL CONFIGURA...

Page 32: ...r writes over the previous character ERASE LINE AFTER CR initially OFF When ON the data from the cursor position to the end of the line will be deleted when a carriage return is entered Page 6 3 1770...

Page 33: ...I Generates an ASCII HORI 011 J 1 2 3 4 5 6 7 8 9 BITS 765 100 101 110 111 p p A Q a q B R b r c s c s D T d t E u e u F v f v G w g w H X h X I y i y J z j z K k L I I M l m N n A 0 0 DEL ZONTAL TAB...

Page 34: ...EPARATOR DELETE DEL DELETE OR RUBOUT Q Some ASCII control codes are generated using non standard keystrokes fJ Will be displayed when Control Code Display option is set ON 1770 T3 systems display_ whe...

Page 35: ...nd line number CTRL P Line A A will position the cursor at the top left corner of the screen CTRL P F Moves the cursor one space to the right CTRL P U Moves the cursor one line up in the same column C...

Page 36: ...ON If you find a problem with your Industrial Terminal System that cannot be resolved contact your local Allen Bradley Sales Repre sentative 1 2 TEST PLUG The CRT Troubleshooting Test Plug Cat No 177...

Page 37: ...monitor 8 3 OPERATING AC LINE VOLTAGE 120V AC or 220 240V AC Selectable 8 4 OPERATING AC VOLTAGE RANGE 98 132V AC 120V 196 250V AC 220 240V 8 5 OPERATING LINE FREQUENCY or 60 Hz Selectable 8 6 FUSE RA...

Page 38: ...January 1983 Supersedes Publication 1770 805 August 1982 Systems Division PC Business 747 Alpha Drive Highland Heights Ohio 44143 P N 955093 35 Artisan Technology Group Quality Instrumentation Guaran...

Page 39: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: