Allen-Bradley 1769-ECL Installation Instructions Manual Download Page 9

Rockwell Automation Publication 1769-IN015D-EN-P - October 2017

9

Compact I/O End Caps/Terminators

Certifications

Additional Resources

These documents contain additional information concerning related products from Rockwell 

Automation.

You can view or download publications at 

http://www.rockwellautomation.com/global/

literature-library/overview.page

. To order paper copies of technical documentation, contact your 

local Allen-Bradley distributor or Rockwell Automation sales representative.

Certifications

(1)

(1)

See the Product Certification link at 

http://www.ab.com

 for Declarations of Conformity, Certificates, and other certification details.

1769-ECL

1769-ECR, 1769-ECRK

c-UL-us

UL Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations, certified for U.S. and 
Canada. See UL File E334470

CE

European Union 2014/30/EU EMC Directive, compliant with:
EN 61000-6-2; Industrial Immunity
EN 61000-6-4; Industrial Emissions

C-Tick

Australian Radiocommunications Act, compliant with:
AS/NZS CISPR 11; Industrial Emissions

Ex

European Union 2014/30/EU ATEX Directive, 
compliant with:
EN 60079-15; Potentially Explosive 
Atmospheres, Protection “n” (II 3 G Ex nA IIC 
T4 X)
 EN 60079-0; General Requirements (Zone 2)

Resource

Description

Compact I/O Modules, publication 

1769-IN088A

Provides information on how to install any 1769 Compact I/O 
module.

1769 Compact I/O Modules Specifications, 
publication 

1769-TD006

Provides technical data for 1769 Compact I/O modules.

Industrial Automation Wiring and Grounding Guidelines, 
publication 

1770-4.1

 

Provides general guidelines for installing a Rockwell 
Automation industrial system.

Product Certifications website,

http://www.rockwellautomation.com/global/certification/
overview.page

 

Provides declarations of conformity, certificates, and other 
certification details.

Summary of Contents for 1769-ECL

Page 1: ...re end caps A 1769 ECR right end cap a 1769 ECRK right end cap or a1769 ECL left end cap terminates the end of the communication bus Use this guide to install either end cap Topic Page Summary of Changes 2 1769 ECL Left End Cap 5 1769 ECL Dimensions 5 1769 ECR and 1769 ECRK Right End Cap 6 1769 ECR and 1769 ECRK Dimensions 7 Specifications 8 Environmental Specifications 8 Certifications 9 Addition...

Page 2: ...Lorsque plusieurs produits sont combinés dans un système le code de température le plus défavorable code de température le plus faible peut être utilisé pour déterminer le code de température global du système Les combinaisons d équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l installation WARNING Explosion Hazard Do not disconnect equipmen...

Page 3: ...s to prevent or minimize the spread of flame complying with a flame spread rating of 5VA V2 V1 V0 or equivalent if non metallic The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of thispublicationmaycontainadditionalinformationregardingspecificenclosuretyperatingsthat are required to comply with certain product safety certifications In addition to this ...

Page 4: ...thedesignandconstructionofCategory3 equipment intended for use in potentially explosive atmospheres given in Annex II to this Directive Compliance with the Essential Health and Safety Requirements has been assured by compliance with EN 60079 15 and EN 60079 0 WARNING This equipment must be installed in an enclosure providing at least IP54 protection when applied in Zone 2 environments This equipme...

Page 5: ...Rockwell Automation Publication 1769 IN015D EN P October 2017 5 Compact I O End Caps Terminators 1769 ECLLeftEndCap 1769 ECLDimensions 1 2 118 mm 4 6 in 15 mm 0 59 in 87 mm 3 43 in ...

Page 6: ...6 Rockwell Automation Publication 1769 IN015D EN P October 2017 Compact I O End Caps Terminators 1769 ECRand1769 ECRKRightEndCap 1 2 3 ...

Page 7: ...Rockwell Automation Publication 1769 IN015D EN P October 2017 7 Compact I O End Caps Terminators 1769 ECRand1769 ECRKDimensions 32 mm 1 26 in 18 mm 0 71 in 118 mm 4 65 in 85 mm 3 35 in ...

Page 8: ...k 0 Ta 60 C 32 Ta 140 F Nonoperating temperature IEC 60068 2 1 Test Ab Unpackaged Nonoperating Cold IEC 60068 2 2 Test Bb Unpackaged Nonoperating Dry Heat IEC 60068 2 14 Test Na Unpackaged Nonoperating Thermal Shock 40 Ta 85 C 40 Ta 185 F Relative humidity 5 95 noncondensing Vibration IEC 60068 2 6 Test Fc Operating 5 g 10 500 Hz Operating shock IEC 60068 2 27 Test Ea Unpackaged Shock DIN rail mou...

Page 9: ...0 CE European Union 2014 30 EU EMC Directive compliant with EN 61000 6 2 Industrial Immunity EN 61000 6 4 Industrial Emissions C Tick Australian Radiocommunications Act compliant with AS NZS CISPR 11 Industrial Emissions Ex European Union 2014 30 EU ATEX Directive compliant with EN 60079 15 Potentially Explosive Atmospheres Protection n II 3 G Ex nA IIC T4 X EN 60079 0 General Requirements Zone 2 ...

Page 10: ...eeds better If you have any suggestions on how to improve this document complete the HowAre We Doing form at http literature rockwellautomation com idc groups literature documents du ra du002_ en e pdf Technical Support Center Knowledgebase Articles How toVideos FAQs Chat User Forums and Product Notification Updates https rockwellautomation custhelp com Local Technical Support Phone Numbers Locate...