Compact I/O End Caps/Terminators

Summary of Changes

This publication contains new and updated information as indicated in the following table.

North American Hazardous Location Approval

Topic 

Page

1769-ECRK module added

Throughout

The following information applies when operating 
this equipment in hazardous locations.

Informations sur l’utilisation de cet équipement en 
environnements dangereux.

Products marked “CL I, DIV 2, GP A, B, C, D” are suitable for 
use in Class I Division 2 Groups A, B, C, D, Hazardous Locations 
and nonhazardous locations only. Each product is supplied 
with markings on the rating nameplate indicating the 
hazardous location temperature code. When combining 
products within a system, the most adverse temperature 
code (lowest “T” number) may be used to help determine 
the overall temperature code of the system. Combinations of 
equipment in your system are subject to investigation by the 
local Authority Having Jurisdiction at the time of installation.

Les produits marqués “CL I, DIV 2, GP A, B, C, D” ne conviennent 
qu'à une utilisation en environnements de Classe I Division 2 
Groupes A, B, C, D dangereux et non dangereux. Chaque produit 
est livré avec des marquages sur sa plaque d'identification qui 
indiquent le code de température pour les environnements 
dangereux. Lorsque plusieurs produits sont combinés dans un 
système, le code de température le plus défavorable (code de 
température le plus faible) peut être utilisé pour déterminer le 
code de température global du système. Les combinaisons 
d'équipements dans le système sont sujettes à inspection par les 
autorités locales qualifiées au moment de l'installation.

WARNING:
Explosion Hazard –

• Do not disconnect equipment 

unless power has been removed or 
the area is known to be 
nonhazardous. 

• Do not disconnect connections to 

this equipment unless power has 
been removed or the area is known 
to be nonhazardous. Secure any 
external connections that mate to 
this equipment by using screws, 
sliding latches, threaded 
connectors, or other means 
provided with this product.

• Substitution of components may 

impair suitability for Class I, 
Division 2.

• If this product contains batteries, 

they must only be changed in an 
area known to be nonhazardous.

AVERTISSEMENT:
Risque d’Explosion – 

• Couper le courant ou s'assurer que 

l'environnement est classé non 
dangereux avant de débrancher 
l'équipement.

• Couper le courant ou s'assurer que 

l'environnement est classé non 
dangereux avant de débrancher les 
connecteurs. Fixer tous les connecteurs 
externes reliés à cet équipement à l'aide 
de vis, loquets coulissants, connecteurs 
filetés ou autres moyens fournis avec ce 
produit.

• La substitution de composants peut 

rendre cet équipement inadapté à une 
utilisation en environnement de Classe 
I, Division 2.

• S'assurer que l'environnement est classé 

non dangereux avant de changer les 
piles.

Summary of Contents for 1769-ECL

Page 1: ...re end caps A 1769 ECR right end cap a 1769 ECRK right end cap or a1769 ECL left end cap terminates the end of the communication bus Use this guide to install either end cap Topic Page Summary of Changes 2 1769 ECL Left End Cap 5 1769 ECL Dimensions 5 1769 ECR and 1769 ECRK Right End Cap 6 1769 ECR and 1769 ECRK Dimensions 7 Specifications 8 Environmental Specifications 8 Certifications 9 Addition...

Page 2: ...Lorsque plusieurs produits sont combinés dans un système le code de température le plus défavorable code de température le plus faible peut être utilisé pour déterminer le code de température global du système Les combinaisons d équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l installation WARNING Explosion Hazard Do not disconnect equipmen...

Page 3: ...s to prevent or minimize the spread of flame complying with a flame spread rating of 5VA V2 V1 V0 or equivalent if non metallic The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of thispublicationmaycontainadditionalinformationregardingspecificenclosuretyperatingsthat are required to comply with certain product safety certifications In addition to this ...

Page 4: ...thedesignandconstructionofCategory3 equipment intended for use in potentially explosive atmospheres given in Annex II to this Directive Compliance with the Essential Health and Safety Requirements has been assured by compliance with EN 60079 15 and EN 60079 0 WARNING This equipment must be installed in an enclosure providing at least IP54 protection when applied in Zone 2 environments This equipme...

Page 5: ...Rockwell Automation Publication 1769 IN015D EN P October 2017 5 Compact I O End Caps Terminators 1769 ECLLeftEndCap 1769 ECLDimensions 1 2 118 mm 4 6 in 15 mm 0 59 in 87 mm 3 43 in ...

Page 6: ...6 Rockwell Automation Publication 1769 IN015D EN P October 2017 Compact I O End Caps Terminators 1769 ECRand1769 ECRKRightEndCap 1 2 3 ...

Page 7: ...Rockwell Automation Publication 1769 IN015D EN P October 2017 7 Compact I O End Caps Terminators 1769 ECRand1769 ECRKDimensions 32 mm 1 26 in 18 mm 0 71 in 118 mm 4 65 in 85 mm 3 35 in ...

Page 8: ...k 0 Ta 60 C 32 Ta 140 F Nonoperating temperature IEC 60068 2 1 Test Ab Unpackaged Nonoperating Cold IEC 60068 2 2 Test Bb Unpackaged Nonoperating Dry Heat IEC 60068 2 14 Test Na Unpackaged Nonoperating Thermal Shock 40 Ta 85 C 40 Ta 185 F Relative humidity 5 95 noncondensing Vibration IEC 60068 2 6 Test Fc Operating 5 g 10 500 Hz Operating shock IEC 60068 2 27 Test Ea Unpackaged Shock DIN rail mou...

Page 9: ...0 CE European Union 2014 30 EU EMC Directive compliant with EN 61000 6 2 Industrial Immunity EN 61000 6 4 Industrial Emissions C Tick Australian Radiocommunications Act compliant with AS NZS CISPR 11 Industrial Emissions Ex European Union 2014 30 EU ATEX Directive compliant with EN 60079 15 Potentially Explosive Atmospheres Protection n II 3 G Ex nA IIC T4 X EN 60079 0 General Requirements Zone 2 ...

Page 10: ...eeds better If you have any suggestions on how to improve this document complete the HowAre We Doing form at http literature rockwellautomation com idc groups literature documents du ra du002_ en e pdf Technical Support Center Knowledgebase Articles How toVideos FAQs Chat User Forums and Product Notification Updates https rockwellautomation custhelp com Local Technical Support Phone Numbers Locate...

Reviews: