Appendix A provides the specifications for the serial converter.
Converter Specifications
Category
Specifications
Electrical
Consumption
(1)
(1)
The serial converter draws the required power from the connected SCANport product.
An external power source is not required.
60mA at +12V DC
Environmental
Temperature
Operating
Storage
0 to +50
°
C (32 to 122
°
F)
-40 to +85
°
C (-40 to 185
°
F)
Relative Humidity
5 to 95% non-condensing
Vibration
Operating
Non-Operating
2.5G @5Hz-2KHz
5 G @5Hz-2KHz
Shock
Operating
Non-Operating
30 G peak acceleration, 11(+/-1)ms pulse width
50 G peak acceleration, 11(+/-1)ms pulse width
Communications
Protocol
RS-232 Serial DF-1
Serial Port Rate
9600
19.2K
38.4K
Data Bits
8
Parity
None
Stop Bits
1
Flow Control
None
Error Detection
CRC or BCC (Auto-Detected)
(2)
(2)
When using DriveExplorer, you can select either CRC or BCC as the checksum.
Regulatory
Compliance
UL
CE
508C and CUL
Mechanical
Dimensions
103.5 x 73.4 x 23.6 mm
(4.08 x 2.89 x 0.93 in)
Weight
2.5 oz. (0.09 g)