background image

RPS15

 User Guide 

Operating the RPS15 

The 

RPS15 

is internally wired to operate from one of the following standard settings: 100V, 120V, 220V, or 240V.  

The

 

unit is shipped pre-wired for the country in which it is to be used. 

   Check that the rear panel is marked to indicate the voltage that is correct for your territory.  The 

power  supply  unit  is  provided  with  an  IEC  type  mains  connector  and  moulded  mains  plug.    Check  that 
this is correct for connection to your wall socket outlet. 

Switch the unit on by setting the front panel POWER ON switch to its ON position.  The three front panel voltage 
rail indicators (+/-17V, +8V, +48V) should light.  The ‘HI TEMP’ indicator should be off during normal operation.  It 
lights to warn when the power supply unit is becoming too hot.  Should that be the case, improve the ventilation or 
lower the air temperatures around the unit. 

    To  avoid  audible  thumps  and  bangs  through  the  speakers,  always  turn  the  console  on  before 

switching  on  the  amplifier  system,  and  turn  the  amplifiers  off  before  switching  off  the  console  power 
supply unit. 

Always switch the power supply unit off before connecting or disconnecting the console power cables, removing 
or installing console modules and any servicing work.  In the event of an electrical storm, or large mains voltage 
fluctuations, immediately switch off the power supply unit and disconnect from the mains supply. 

 

Cleaning the Unit 

The 

RPS15

  does  not  use  any  internal  filters.    Air  is  drawn  through  the  fan  grille  on  the  rear,  blown  through  a 

heatsink  tunnel  and  out  through  ventilation  slots  in  the  front  panel.    It  is  not  necessary  to  open  the  unit  for 
cleaning.  Simply keep the fan and ventilation slots free of dust and dirt using a vacuum cleaner and dry, lint free 
cloth.  Do not use liquid cleaners or compressed air to clean the unit. 

  Always switch the unit off when inspecting or cleaning it. 

 

Replacing the mains fuse 

The AC mains fuse is located on the rear of the 

RPS15

 unit next to the AC mains connector.  In the event of a 

mains surge or under-rated fuse value, the fuse will rupture.  Switch off the power supply and remove the mains 
lead plug from the “MAINS INPUT” socket on the rear of the unit.  Check the fuse and replace if necessary.  In the 
event of repeated failure of the mains fuse, consult your Allen & Heath service agent. 

In the unlikely event of an internal DC rail fuse failure, consult your Allen & Heath service agent or Allen & Heath 
technical support. 

   TO  AVOID THE RISK  OF  FIRE REPLACE  FUSE WITH  THE CORRECT TYPE  ONLY,  AS INDICATED 

ON THE UNIT.

 

AC~ mains input voltage 

Fuse type 

A&H Part No. 

100V – 120V ± 10% 

220V – 240V ± 10% 

T 10A L 250V 20mm 

T 8A L 250V 20mm 

AL3455 

AL0487 

 

Summary of Contents for RPS15

Page 1: ...Studio Console Power Supply USER GUIDE Publication AP8234 RPS15...

Page 2: ...EATH distributor or agent in your country as soon as possible for repair under warranty subject to the following conditions Conditions of Warranty The equipment has been installed and operated in acco...

Page 3: ...e ground connection in the power cord Water and moisture To reduce the risk of fire or electric shock do not expose the power supply unit to rain or moisture or use it in damp or wet conditions Do not...

Page 4: ...e power supply unit cosmetics avoid placing heavy objects on the unit scratching the surface with sharp objects or subjecting the power supply unit to rough handling and vibration Environment Protect...

Page 5: ...OCUMENTATION including Safety Sheet AP3345 this user guide AP8234 and the Registration Card The RPS15 The slimline RPS15 power supply unit is a high performance low noise linear power supply producing...

Page 6: ...ion of the unit from other equipment particularly that which carries low level audio signals to avoid any possible interference pick up For this reason power supply units supplied with Allen Heath GS...

Page 7: ...In the event of an electrical storm or large mains voltage fluctuations immediately switch off the power supply unit and disconnect from the mains supply Cleaning the Unit The RPS15 does not use any...

Page 8: ...T 16AL 250V 20mm A H Part no AL8154 F2 17 5V T 16AL 250V 20mm A H Part no AL8154 F3 48V T 1 6AL 250V 20mm A H Part no AL0466 F4 12V T 6 3AL 250V 20mm A H Part no AL0395 DC Outputs DC Voltage Rail Outp...