2
IDR-in/out
User Guide AP4774
The
iDR-in
and
iDR-out
expanders can be rack mounted or free standing. There are no
user controls on the front panel, only the status and assignable LEDs. Allow a minimum of
75mm clearance behind the unit for the connectors and cables. Ensure adequate
ventilation to the side of and behind the unit.
It is shipped with its rack ears fitted and its feet removed ready to be mounted in a standard
19” equipment rack. 1U rack space is required. For desk mount operation remove the two
rack ears using a Torx (star head) T10 screwdriver. Fit the four plastic feet provided by
pressing them into the underside.
Make sure you have read the Important Safety
Instructions printed earlier. Also check that your local
mains supply is compatible with that printed on the rear
panel of the unit. Ensure that the correct mains lead with
moulded plug and IEC connector has been supplied. For
your own safety and optimum performance make sure the
system is correctly grounded.
To avoid any unexpected audible clicks or thumps
always turn connected power amplifiers down or off before
switching the iDR or any other signal equipment on or off.
Turning the expander on or off
First make sure
the unit is correctly plugged up and connected to the
iDR-4(8)
.
This is described below. Turn the unit on by pressing the rear
panel power ON/OFF switch. The power LED lights up. The
link LED lights if the DR-Link connection is established with the
iDR-4(8)
. The lock LED lights once the link is established and
audio is correctly communicated with the
iDR-4(8)
. The iDR
System Manager detects the presence of the expander.
If one or more of the LEDs do not light then check that the
cables are correctly fitted and the
iDR-4(8)
is functioning
normally.
Checking for expanders
You can use the front
panel
iDR-4(8)
Setup menus to check if any expanders are
connected and recognised. This is useful when the expanders
are located far away from the main unit. With the face plate
removed access menu *8 Diagnostics and scroll to Audio Exp.
Refer to the
iDR-4
user guide AP5230 or
iDR-8
user guide
AP4530 for further details.
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
47-63Hz ~ 25W MAX
100 - 240V~
THIS APPARATUS MUST BE EARTHED.
WARNING
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
FUSE: T500mAL
power
lock
link
AUDIO INPUT EXPANDER
power
lock
link
iDR-in
lock
link
power
AUDIO OUTPUT EXPANDER
iDR-out
48mm
1.9"
44mm
1.7"
1U
232mm
9.1"
307mm
12"
75mm
3"
iDR-in and iDR-out EXPANDERS
Remove 2x rack ears
Fit 4x feet
M3 Torx T10
483mm
19"
443mm
17.4"
*8 Diagnostics
Audio Exp:In/Out