43
H
ARD
R
ESET
Should the console memory become corrupted it can be
reset to the factory defaults by performing a hard reset :
Hold down
EDIT GROUP + PREVIEW GROUP
while
powering up the console. The following condition set :
All console mutes turned on.
Patch display shows
0
All mute patches cleared (mutes turned off).
All mute groups cleared (mutes turned off).
MIDI channel set to 16.
No mute safes set.
No solo safes set.
E
RROR
M
ESSAGES
In the event of an automation error an error message is
displayed. This is a two part message comprising an error
number and an error code. For example, should a MIDI
Dump In error be detected the following
error number
will
be displayed :
En0
Press any automation key to show the
error code
which
gives further information about the error.
Ec1
Press any automation key to clear the error display and
return the system to normal operation.
The following
ERROR MESSAGES
apply :
NUMBER
CODE
DESCRIPTION
0
MIDI Dump In error
0
Packet 0 not received
1
Missing packet
2
Buffer overflow
3
Checksum error
4
Dump timeout
1
EEPROM memory access error
0
Write error
1
Page write error
2
Read error
3
Page read error
4
Byte read error
2
Power brown-out detected