background image

DX164-W User Guide 

 

AP11446 Issue 2 

 

 

Specification 

Mic/Line XLR Inputs 

Balanced XLR, +48V phantom power 

Mic/Line Preamp 

Fully recallable 

Input Sensitivity 

-60 to +15dBu 

Analogue Gain 

+5 to +60dB, 1dB steps 

Pad 

-20dB Active PAD 

Maximum Input Level 

+30dBu (PAD in) 

Input Impedance 

 

>4kΩ (Pad out), >10kΩ (Pad in)

 

Mic EIN 

-127dB with 150

  source 

 

 

Analogue XLR Outputs 

Balanced, Relay protected 

Output Impedance 

<75Ω

 

Nominal Output  

+4dBu = 0dB meter reading 

Maximum Output Level  

+22dBu 

Residual Output Noise  

-92dBu (muted, 20-20kHz) 

 

-90dBu (muted, 20-40kHz) 

 

 

Operating Temperature Range 

0

°

C to 35

°

C  (32

°

F to 95

°

F) 

Power

 

 

Mains Voltage Operating Range 

100-240V AC, 50/60Hz 

Mains Power Consumption 

35W max 

DC Input 

12V DC, 3A max 

 

 

Dimensions and Weight

 

Width x Depth x Height x Weight 

DX164-W 

210 x 87 x 210 mm x 3.2kg 

(8.25” x 3.5” x 8.25” x 7lbs)

 

 

 

 

 

Summary of Contents for DX164-W

Page 1: ...g mounted in a floor pocket mounted on a wall or flush mounted in a wall Different power options are provided to suit the application This product must be installed by a professional installer or qualified electrician DX164 W requires dLive firmware V1 7 or higher Contents Check that you have received the following with your DX164 W unit Optional gland module part number 004 1097 Mounting frame AH...

Page 2: ...nection to a second DX164 W or DX168 unit DC 12V Input Can be used instead of AC mains to power the unit where adequate DC distribution is provided in a building Can also be used as a backup power supply in case of mains failure Mains power input The built in universal PSU accepts voltages from 100 to 240V AC 50 60Hz A module with IEC inlet is fitted by default An optional module is provided for p...

Page 3: ...ower indicator The preamps are built into the DX164 W and their Gain Pad and 48V are controlled from the mixer via the DX link The 48V indicator detects voltage at the socket whether supplied by the DX164 W or received from an external source Output sockets Balanced XLR outputs operating at nominal 4dBu level ...

Page 4: ... screws for the type of wall then align the threaded inserts on the sides of the DX164 W with the frame and secure the unit in place with the 6x M4 6mmT20 screws provided Flush mounting in a wall Use the mounting frame AH11504 in the orientation shown below Align the threaded inserts on the sides of the DX164 W with the frame and secure the unit in place with the 6x M4 6mm T20 screws provided Conn...

Page 5: ...ns wiring for permanent installation must be performed by a qualified electrician See instructions later in this guide To replace the IEC module Remove the 4 screws using a Torx T8 driver Pull out the module and unplug the harness at the bottom Fit the cable gland to the gland module Run the mains cable through the gland Wire the mains to the screw terminal paying attention to polarity and earth a...

Page 6: ...DX164 W User Guide AP11446 Issue 2 Dimensions 87 00 210 00 210 00 120 84 ...

Page 7: ...N 127dB with 150Ω source Analogue XLR Outputs Balanced Relay protected Output Impedance 75Ω Nominal Output 4dBu 0dB meter reading Maximum Output Level 22dBu Residual Output Noise 92dBu muted 20 20kHz 90dBu muted 20 40kHz Operating Temperature Range 0 C to 35 C 32 F to 95 F Power Mains Voltage Operating Range 100 240V AC 50 60Hz Mains Power Consumption 35W max DC Input 12V DC 3A max Dimensions and ...

Page 8: ...l A limited one year manufacturer s warranty applies to this product the conditions of which can be found at www allen heath com legal By using this Allen Heath product and the software within it you agree to be bound by the terms of the relevant End User Licence Agreement EULA a copy of which can be found at www allen heath com legal Register your product with Allen Heath online at http www allen...

Reviews: