Allegro Industries 9910 Series User Manual Download Page 4

WARNINGS - LIMITATIONS

 

Read, understand, and follow the Warnings - Limitations listed below: 

 
1.  Do not use this respirator in any way that does not agree with this User Manual or any 

applicable regulation. 

 

2.  This respirator must be used in accordance with a complete respirator program, such as the 

one specified in 29 CFR 1910.134. 

 

3.  Do not use this respirator in enclosed or poorly ventilated spaces where a high concentration 

of contaminants can occur or in an oxygen deficient atmosphere.  Use only in adequately 
ventilated areas containing sufficient oxygen to support life. 

 

4.  This respirator does not supply oxygen.  Use only in atmospheres containing 19.5% oxygen. 

 

5.  Do not use this respirator in any atmosphere that is immediately dangerous to life or health 

(IDLH), which means conditions that pose an immediate threat to life or health, or conditions 
that pose an immediate threat of severe exposure to an air contaminant or contaminants which 
are likely to have an adverse delayed effect on life or health. 

 

6.  The exposure limits specified in OSHA regulations, in the regulations of other government 

agencies, and in the most recent authoritative scientific literature shall be observed when the 
respirator described in this manual is used. 

 

7.  This respirator shall not be used in any manner contrary to the recommendations contained on 

the package label and on the Material Safety Data Sheet (MSDS) or similar document 
available from the manufacturer or supplier of the substance or substances being used. 

 

 8.  Do not use this respirator during abrasive blasting (including sandblasting). 

 

 9.   Use only ALLEGRO INDUSTRIES component parts and combinations of parts to assemble 

or repair this respirator.  Consult the parts list and approval label for approved parts.  Use of 
non-approved parts voids the NIOSH approval and may result in bodily injury or death. 
 

10.  This respirator should be inspected and any necessary repairs made before each use. It must 

be cleaned, sanitized, dried and stored according to the directions in this manual. 

 
11.  Do not use this respirator if you have a concern that the air being supplied to the respirator 

facepiece is not of the quality and quantity described herein. 

 

12.  It is important that the pressure and flow of the air entering the supplied air hose from the air 

supply be controlled and that it meets the requirements specified in this instruction manual. 

 

13. During use, if any decrease in air flow to the hood is noticed, leave the contaminated area 

immediately, remove the hood and inspect it for any damage such as tears, holes or rips in the 
material.  If any damage is noticed, dispose of the hood immediately as instructed by your 
supervisor. 

 
 

Summary of Contents for 9910 Series

Page 1: ...UPPLIED AIR HOOD RESPIRATORS P N 9910 P N 9910R P N 9910D P N 9910DS P N 9912D Read and understand all instructions before using this product Open carton carefully and inspect product for damage cause...

Page 2: ...Safety Precautions Warnings and Limitations Cautions and Limitations Parts List Air Quality and Volume Inlet Pressure Donning Doffing Instructions Hood Replacement Maintenance and Storage Specificatio...

Page 3: ...nstant flow of air to the hood when connected to an external air source When used with an approved air line at a pressure of 6 to 40 PSI air is delivered to the respirator at a rate exceeding 6 CFM 17...

Page 4: ...used 7 This respirator shall not be used in any manner contrary to the recommendations contained on the package label and on the Material Safety Data Sheet MSDS or similar document available from the...

Page 5: ...ators S Special or Critical User Instructions and or specific use limitations apply Refer to User Instructions before donning S SPECIAL OR CRITICAL USER S INSTRUCTIONS Dual Hose Usage The blue unrelat...

Page 6: ...9910 02 Head Band Assembly Standard 3B 9910 03 Head Band Assembly Ratchet Optional 4 9910 25A Peel Off Lens Cover Not Shown 9910 04 Breathing Tube Assy w o Waist Belt Not Shown 9900 02 Waist Belt 5A...

Page 7: ...Attachment and the length of the supplied air hose see Special User Instructions Warning ALLEGRO INDUSTRIES air hose is approved for use with this Supplied Air Hood Respirator Using any other hose wil...

Page 8: ...e breathing tube into the replacement hood Be sure to insert the breathing tube fully into the collar of the hood See drawing Underside View Underside View for 9910 9910R 7 Install the white clamp ove...

Page 9: ...pirator and may result in bodily injury or death The hood and its components used by an individual should be inspected and if possible cleaned and sanitized after each day of use The 9910D and 9910DS...

Page 10: ...r to those components listed on the NIOSH label in this manual STORAGE Store the Supplied Air Hood away from dust sunlight temperature extremes moisture and chemicals Before storing these hood assembl...

Page 11: ...ect indirect incidental special or consequential arising out of sale use or misuse of ALLEGRO INDUSTRIES products or the user s inability to use such products Refer to this Users Manual for proper use...

Page 12: ......

Reviews: