background image

Magnetic Card Reader

Models SMR-10 and SMR-20
Installation and Maintenance Instructions

23884539

General

The SMR10/20 family of magnetic stripe card readers are designed for reading standard or high-coercivity magnetic stripe 
cards. The SMR20 also provides a 12-key keypad for PIN entry. The SMR10/20 provides a TTL interface. The following 
paragraphs describe instructions for installing and maintaining the card reader.

Mounting the Reader

Find a suitable location to anchor the reader mounting bracket. The reader may be mounted vertically or horizontally. See 
recommended orientation. The mounting of the reader does not require a junction box. However,rigid conduit is required for 
outdoor application. A single gang junction box may be used to provide a transition to rigid conduit.  If a single gang junction box 
is used, a wall plate (optional) may be used to cover the junction box. The reader is then secured to the mounting bracket using 
a screw. Refer to figures for reader dimensions and typical junction box usage.

Recommended

Not Recommended

Reader Wiring

The reader has a RJ-11 modular jack for easy field connection. A small piece of pre-terminated cable is supplied with each 
standard reader for field wiring. The pre-terminated cable has nonstandard color. Refer to pin number if the pre-terminated cable 
is not used. Cable with wires of 24AWG or larger are recommended for field wiring.

www.schlage.com

(877) 671-7011 

Contents

General .....................................................................................1
Mounting the Reader ................................................................1
Reader Wiring ...........................................................................1
Connecting the Keypad ............................................................2
Weather-Proofing the Reader ...................................................2
TTL Interface ............................................................................2
Grounding the Reader ..............................................................3
Keypad Data and Tamper Monitor Signalling ............................3
Reader Verification ...................................................................3

Maintenance .............................................................................3
DIP switch/Jumper setting ........................................................4
SMR10/20 Standard Format Code Summary ..........................5
Specification .............................................................................6
Product Identification ................................................................6
Reader Mounting Dimensions ..................................................7
Warranty ...................................................................................8
Liability ......................................................................................8

Summary of Contents for Schlage SMR-10

Page 1: ...on box is used a wall plate optional may be used to cover the junction box The reader is then secured to the mounting bracket using a screw Refer to figures for reader dimensions and typical junction...

Page 2: ...not use sealant to seal reader case to the wall Doing so will trap water in the reader and may cause damage to the reader TTL Interface The TTL interface has the standard 5 wire interface widely used...

Page 3: ...zero bits otherwise sends data as is Tamper monitor enabled 3 Mag stripe data output with zero trim reverse read correction and error filter enabled using CLOCK DATA signaling Tamper monitor disabled...

Page 4: ...ill flash Otherwise the red LED will flash and the buzzer will sound two short beeps to indicate an error The LED input can be used to verify the LED function and the buzzer input for the buzzer funct...

Page 5: ...mension 1 95 50mm W x 1 30 33mm H x 5 50 140mm L Weight 10 oz 284 g nominal Material Case Die cast aluminum gray powder coat standard Mounting stainless steel Wall plate 18 CRS gray powder coat standa...

Page 6: ...l Wall Plate part WP10 6 30 160 3 30 84 1 38 35 1 23 31 1 40 36 4 00 102 2X 0 18 4 5 2 75 70 Fitting Rigid Conduit to Junction Box WALL OPENING FOR J BOX Rigid Conduit 1 Gang Box WALL STUD Wall Openin...

Page 7: ...and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose Returned units are repaired or replaced from a stock of reconditioned units Returns m...

Page 8: ...Allegion 2017 Printed in U S A 23884539 Rev 08 17 b...