Allegion 8310-880 Instructions Manual Download Page 3

75.0023.01 ALLEGION 8310-880 900 MHZ TRANSMITTERS_RECEIVERS 20200612   

Page 3 of 8

75.0023.01 ALLEGION 8310-880 900 MHZ TRANSMITTERS_RECEIVERS 20200612   

Page 3 of 8

WIRING

POWER

RELAY CONTACTS

LABEL

12 – 24

12 – 24

COM

NO

NC

WIRE COLOR

Red (+)

Black (-)

white

green

yellow

TERMINAL

1

2

3

4

5

DESCRIPTION

Control or Transformer power

Control Common

Control Activation

Typically not used

TOUCHLESS RETROFIT TRANSMITTER

RECEIVER

In most applications for existing hard-wired touch push plates, only two (2) wires are installed which 
run within the wall from the push plate to the door control for activation.  

The 900 MHz Touchless Retrofit Transmitter allows an existing, hard-wired, touch, push plate to be 
retrofitted with a new touchless plate that requires four (4) wires (2 wires for power and 2 wires for 
activation) without running additional wires.  

This is achieved by use of a powered wireless transmitter and wireless receiver.

1. Remove existing touch push plate and disconnect the two (2) existing in-wall wires from the 

push plate and door control activation.

2. Connect the green and white wires to the new touchless plate activation output (see image, 

right). 

3. Parallel the red and black wires with the two (2) existing in-wall wires and connect them to the 

new touchless plate power input (see image below).

4. Mount new touchless plate.

5. Connect the two (2) existing in-wall wires to the power source in the door control header.

6. Install the 900 MHz wireless receiver in the header (sold separately).

ACT

COM  NO

PWR

+       -

Touchless

Retrofit Transmitter

TOUCHLESS PLATE

Summary of Contents for 8310-880

Page 1: ...LEGION 8310 880 900 MHZ TRANSMITTERS_RECEIVERS 20200612 Page 1 of 8 ENGLISH DESCRIPTION RECEIVER TRANSMITTERS Hard wired transmitter with flag connectors Touchless retrofit transmitter for touch to to...

Page 2: ...er than 5 seconds Constantly be aware of pedestrian traffic around the area Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door...

Page 3: ...push plate to be retrofitted with a new touchless plate that requires four 4 wires 2 wires for power and 2 wires for activation without running additional wires This is achieved by use of a powered w...

Page 4: ...lt DIP SWITCH 2 Pulse only OFF 0 5 sec Hold Time Relay remains active 0 5 seconds after transmitter is pressed standard hold or released extended hold ON 10 sec Hold Time Relay remains active 10 secon...

Page 5: ...all push plate PROGRAMMING cont SIGNAL STRENGTH INDICATOR VESTIBULE CONFIGURATION STANDARD TRANSMITTERS ONLY RECEIVER TRANSMITTER LEARN1 Outer outer 1 No Delay inner 2 Delay vestibule 4 No Delay Inner...

Page 6: ...Replace 3 volt CR2032 battery observing polarity and reassemble LOW BATTERY INDICATOR Low battery is indicated after pressing button by 3 transmitter LED blinks All transmitters must ONLY be powered w...

Page 7: ...l FCC IC TECHNICAL SPECIFICATIONS Specifications are subject to change without prior notice All values measured in specific conditions TROUBLESHOOTING Weak signal Receiver antenna wire poorly position...

Page 8: ...Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas prod...