Push the Menu button to enter the system menu. Push the Menu button again to toggle through the menu
items. The available menu items are:

3.4.1. Load Preset

Turn the rotary encoder to select the preset you wish to load. Push the rotary encoder to select it, then turn it
again to select "YES" and confirm again by pushing the rotary encoder knob. The preset is loaded and all
settings are applied immediately. All settings that were in the unit prior to loading the preset will be erased.
This action can not be undone.
The presets contain all filter, dynamics, gain settings etc; in other words, everything that makes out a
loudspeaker configuration. Presets do NOT contain the name of the unit, network configuration, automatic
standby delay, user access rights and passwords.

3.4.2. Save Preset

Turn the rotary encoder to select the location of the preset. If that location is not empty, the preset in that
location will be overwritten. This action can not be undone.
The system will ask you to give a name to the preset name. Select a character in the cursor position by
turning the rotary encoder; pushing the rotary encoder confirms the character selected and moves the cursor
to the next character to edit. Pushing the exit/ESC button erases the last confirmed character. Once the
name is set up, push the menu  button again. If you want to continue storing the preset, select Yes by turning
the rotary encoder and confirm by pushing it. To cancel, push the exit  button. Now your preset is saved in
the selected location.
The presets contain all filter, dynamics, gain settings etc; in other words, everything that makes out a
loudspeaker configuration. Presets do NOT contain the name of the unit, network configuration, automatic
standby delay, user access rights and passwords.

3.4.3. Access Level

The ASP-2M6 has the option of locking away the front panel controls to avoid tampering of settings by
unauthorized persons. To lock the unit, select "Locked" by turning the rotary encoder, and push it to confirm.
The system will ask you to enter a password. Select a character in the cursor position by turning the rotary
encoder; pushing the rotary encoder confirms the character selected and moves the cursor to the next
character to edit. Pushing the exit/ESC button erases the last confirmed character. Once the password is set
up, push the menu  button again and the unit will be locked. 
ATTENTION: Make sure to remember the password! When the unit is locked and you forgot the password, it
is not possible to unlock it without contacting your local service representative.
To unlock the unit select "Unlocked" and enter the password. The password is automatically checked after
each entered character, and the unit will exit the system menu when the password is confirmed.
The default password is "Password".

3.4.4. Version Information

By pushing the rotary encoder, the display toggles through the version information about the unit (serial
number, firmware version), as well as some parameters like IP address, subnet mask, MAC address etc.

Page 12/13

Summary of Contents for ASP-2M6

Page 1: ...ALLDSP ASP 2M6 User Manual for ALLDSP ASP 2M6 Page 1 13...

Page 2: ...controls Alternatively the ASP 2M6 can be configured completely via a remote connection to a PC MAC iPad or iPhone Please refer to the Software User Manual for details on the remote control applicati...

Page 3: ...urce at installation Connect this equipment only to the power source indicated on the equipment rear panel To reduce the risk of fire or electric shock refer servicing to qualified service personnel o...

Page 4: ...he input level exceeds 20dBu 1 1 3 Function Buttons The function buttons allow direct access to all editing and navigating functions See section three for a detailed description on the functions of ea...

Page 5: ...Bu max electronically balanced 1 2 5 AES3 Inputs The digital input of the ASP 2M6 offers two input channels on one electronically balanced XLR connector The input will accept AES3 input signals at 44...

Page 6: ...lication has an auto discovery tool that will automatically connect to any unit found on the network Please refer to the Software Manual available on our website for details on the control software No...

Page 7: ...put level control From the crossover there may be additional filters that are employed to improve the response of your speakers There may also be limiters set up to keep your amplifiers from going int...

Page 8: ...t the input channel you wish to edit by pressing the channel button below the VU meter for the corresponding channel once Make the first settings with the output turned low or muted To toggle through...

Page 9: ...g the rotary encoder Press the rotary encoder to select the parameters The available parameters are Frequency 20Hz to 20kHz Gain 12dB to 12dB Q 0 2 to 25 Enabled On or Off Type Bell High Shelf Low She...

Page 10: ...ss Filter Adjust the Low Pass Filter frequency by turning the rotary encoder You can switch the low pass filter off by turning the rotary encoder up clockwise until the frequency passes 20kHz Press th...

Page 11: ...in dB Oct 3 3 7 Compressor The compressor is a true RMS compressor Turn the rotary encoder to set the threshold Press the rotary encoder to select the parameters The available parameters are Threshol...

Page 12: ...ncoder and confirm by pushing it To cancel push the exit button Now your preset is saved in the selected location The presets contain all filter dynamics gain settings etc in other words everything th...

Page 13: ...entical to the original fuse If you want to dispose this product do not mix it with general household waste There is a separate collection system for used electronic products in accordance with legisl...

Reviews: