Important Safety Information 

í ! wb Lb Dﱡ

 

This manual contains important instructions for APS1000-12 & APS2000-24 models that 
shall be followed during installation and maintenance of the inverters. 

General Safety Precautions 

1. 

Before installing and using the inverter/charger, read all instructions and 
cautionary markings on the inverter/charger and all appropriate sections of this 
guide. Be sure to read all instructions and cautionary markings for any equipment 
attached to this unit. 

2. 

Install this unit away from direct sun light and where is not exposed to water 
sprinklers. 

3. 

To reduce risk of fire hazard, do not cover or obstruct the ventilation openings. 
Do not install the inverter/charger in a zero-clearance compartment. Otherwise 
overheating may occur.\ 

4. 

Use only attachments recommended or sold by the manufacturer. Doing 
otherwise may result in a risk of fire, electric shock, or injury to persons. 

5. 

To avoid a risk of fire and electric shock, make sure that existing wiring is in good 
condition and that wire is not undersized. Do not connect the inverter/charger 
with damaged or substandard wiring.  

6. 

Do not operate the inverter/charger if it has received a sharp blow, been 
dropped, or otherwise damaged in any way. If the inverter/charger is damaged, 
read the warranty section. 

7. 

Do not disassemble the inverter/charger. It contains no user-serviceable parts. 
See warranty for instructions on obtaining service. Attempting to service the 
inverter/charger yourself may result in a risk of electrical shock or fire. Internal 
capacitors remain charged after all power is disconnected. 

8. 

The inverter contains more than one live circuit (batteries and AC line). Power 
may be present at more than one source. To reduce the risk of electric shock, 
disconnect both AC and DC power from inverter/charger before attempting any 
maintenance or cleaning or working on any circuits connected to the 
inverter/charger. Turning off controls will not reduce this risk.  

9. 

Use insulated tools to reduce the chance of short-circuits when installing or 
working with the inverter or the batteries. 

Precautions When Working with Batteries 

1. 

Make sure the batteries are well ventilated. Avoid blocking enclosure vents. 

2. 

Never smoke or allow a spark or flame near the inverter or batteries. 

3. 

Use caution to reduce the risk of dropping a metal tool on the batteries. It could 
spark or short circuit the battery or other electrical parts and could cause an 
explosion. 

4. 

Remove all metal items, like rings, bracelets, and watches when working with 
lead-acid batteries. Lead-acid batteries produce a short circuit current high 
enough to weld metal to skin. 

5. 

Make sure someone is close enough to aid should anything dangerous occur 
when you’re working near a lead-acid battery.  

Summary of Contents for APS1000-12

Page 1: ...POWER INVERTER APS1000 12 APS2000 24...

Page 2: ...sis System Architecture 4 Product Overview 4 Installation 5 Unpacking and Inspection 5 Preparation 6 Mounting The Unit 6 Battery Connection 7 AC Input Output Connection 9 Electrical Performance 11 LCD...

Page 3: ...nty section 7 Do not disassemble the inverter charger It contains no user serviceable parts See warranty for instructions on obtaining service Attempting to service the inverter charger yourself may r...

Page 4: ...restored the inverter transfer to the AC source and recharges the batteries The series inverter can also serve as a central hub of renewable energy system Set the series inverter to battery priority m...

Page 5: ...amp Home entertainment electronics television VCRs video gate consoles stereos musical instruments satellite equipment Pure sine wave output AC Battery priority Via function DIP switch Auto generator...

Page 6: ...Battery Type Selector Charge Current Adjuster 25 50 75 100...

Page 7: ...ERTER OFF ON Connectors 8 9 and 10 are extended to the inverter front panel for easy wiring IMPORTANT When the inverter is used to power Gate Operators switch must be in the ON position Not the ON Pow...

Page 8: ...all the unit Do not install the inverter on ammable construction materials Mount on a solid surface Install the inverter at eye level in order to read the LCD display clearly For proper air circulatio...

Page 9: ...series inverters use 4AWG cable that meet or exceed this requirement If there is a need to replace the battery cables you must use the proper size to handle the power If Batteries need to be moved out...

Page 10: ...Sealed GEL AGM Lead Acid Batteries 3 Connect ring terminals of battery cable into inverter battery connector and make sure bolts are tightened Make sure polarity is correct at both ends of the cable b...

Page 11: ...G It s very important for system safety and ef ciency operation to use appropriate cable for Grid connection To reduce risk of injury please use the recommended proper cable size as below AC Wiring We...

Page 12: ...onnect protective earth conductor rst Ground green L LINE black N Neutral white 120V AC 60Hz 1000W L L N N INPUT OUTPUT RLY 1 COMMON N O RLY 2 COMMON N O AC output load 5 Make sure all wires are secur...

Page 13: ...120Vac 75Vac 2 80Vac 2 140Vac 140Vrms 135Vac 2 2 30A 40A APS1000 12 APS2000 24 Same as Input Waveform...

Page 14: ...000VA 4 000VA Instant Reverse Gate Motors Two 1 2 HP or One 1HP Instant Reverse Gate Motors Four 1 2 HP or Two 1HP 11Vdc 0 3Vdc 22V 11V 22Vdc 0 6Vdc 10 5Vdc 0 3Vdc 21Vdc 0 6Vdc 16Vdc 0 3Vdc 32Vdc 0 6V...

Page 15: ...120Vac 75 140Vac 10 5 15 7Vdc 35A APS1000 12 APS2000 24 21V 31 4Vdc 15 7Vdc 31 4Vdc Alarm beeps 0 5s second Fault after 60s...

Page 16: ......

Page 17: ...the gate on AC utility power failure Once AC utility power fails the relay will trigger the signal 120V AC 60Hz 1000W L L N N INPUT OUTPUT RLY 1 COMMON N O RLY 2 COMMON N O Relay Function for gate ope...

Page 18: ...ch work in a wide voltage range the input AC range can be customized to 75 140VAC this helps to power loads with the most AC input power without switching to battery bank For gate operators we use the...

Page 19: ...cations where a lot of brow outs happen Battery voltage restart After low battery voltage shut off 10 5V for 12V model 20V for 24V model the inverter is able to restore operation after the battery rec...

Page 20: ...By restarting the inverter Turn it OFF and back ON...

Page 21: ...Indicators on display panel Note indicator ON x indicator OFF blink shows the indicator blinking about 0 5s on and 0 5s off...

Page 22: ...etting no output voltage power switch in wrong position set power switch to power ON down position wire connections are incorrect inverter is damaged not charging inverter battery selector in wrong se...

Page 23: ......

Page 24: ...420 00233 03 POWER INVERTER...

Reviews: