Alke AL-4 Series User, Service And Installation Manual Download Page 9

Version 2: March 2020 

manual: 0009 0231EN 

Schematic diagram electronic ignition device 

Timing diagram electronic ignition device 

 

 

 

Typical lay-out for the connection of the electric lines

 

 

To control box 

To additional zones 

SW1  Switch on/off 
SW2  Switch high/low fire 
BR 

Brown 

BL 

Blue 

YE 

Yellow/Green = Earth 

Ei 

Electronic Ignition Device 

Solenoid for high/low 

 

 

NB: dotted line is only applicable for 
the 

…S… models 

 

 

6. 

Operation 

New heaters  

New heaters need a short cleaning period before they are ready for operation. Fire the heaters for at least 30 
minutes on full capacity to burn-off oily and greasy remnants of the production. Make sure that after 30 minutes 
all smoke and smell is disappeared. 
 

Ignition of the heater  

Warning:  after  a  manual  operated  heater  is  extinguished  (intentionally  or  unintentionally)  wait  always  for  3 
minutes before (re)ignition. This is a worldwide safety rule and intended to ventilate unburned gases away and 
to leave enough time for the thermocouple device to close. 
Note:  ignition  shall  always  be  done  in  high  fire.  To  do  so,  the  gas  pressure  shall  be  adjusted  at  maximum 
(nominal) pressure as indicated on the data plate, solenoid valves shall be in open or high fire position. If desired, 
the heat input of the heater can be set to low fire after about 30 seconds after ignition. 
Note: If 10 ignition attempts are made in sequence within a short interval (<120 seconds per ignition attempt) 
the electronic ignition device will fall into a safety lockout and needs a reset (cool down period) for 20 minutes. 
During the reset, leave the power on to feed the internal reset timer. 
 

Manual operated heaters 

(All models, except models with 

…Ei… or …SEi…) 

 
Ignition of the heater 
1)  Open all gas taps and turn the gas pressure regulator (if mounted) on nominal pressure, open the solenoid 
valve (S)(if mounted) by electricity. (Fig. 2a, 2b). In case the heater has a high/low fire setting, ignite always in 
high fire position. 
2)  Keep a flame of a BBQ lighter (or long match) in the ignition hole of the burner gauze directly above the 
ceramic stone. (Fig. 3a).   
3)  Press the knob of the gas safety device, ignite the burner, and wait for 10-25 seconds after ignition before 
releasing the knob. (Fig. 4). 
4)  The burner will stay on now.   
5)  Repeat al steps again in case the burner directly extinguishes. 
 

 

Summary of Contents for AL-4 Series

Page 1: ...L 7 Series Atmospheric ceramic gas infrared heaters for outdoor use Country of destination GB IE MT General international manual AL 7 SEi AS AL 4 F AS AL 6 FSEi AS Alke BV Industrielaan 11a 3925 BD Sc...

Page 2: ...Version 2 March 2020 2 manual 0009 0231EN Fig 1a Fig 1b Fig 1c Fig 1d Fig 2a Fig 2b Fig 3a Fig 3b Fig 4 Fig 5a Fig 5b Fig 5c Fig 6...

Page 3: ...the system is safe again Consult an installer If a heater is not safe to use anymore close the gas supply and electricity to the heater so that nobody accidentally can operate the heater Contact a ser...

Page 4: ...dealer in case the carton box and heater are damaged Before leaving the factory all the heaters are operated and tested by the manufacturer on gas for 5 minutes Note that due to this the burner and re...

Page 5: ...space The heaters are intended for outdoor use only or amply ventilated areas but not for indoor heating See fig 1a 1b 1c When local regulations allow it there are no safety objections to use the heat...

Page 6: ...objects Ventilation around the heater Check if there is sufficient space for the combustion gases to vent away but also if there is enough fresh air available at the inlet of the venturi 10 or 33 to t...

Page 7: ...connections of the gas regulator and the gas valve of the gas cylinder are of the same type Check with the gas cylinder supplier for the correct size of gas regulator and check whether the capacity is...

Page 8: ...er try to do gas repairs by yourself Do not use the heater anymore until the problem is solved 5 Electrical information only heaters with S Ei or SEi as a part of the model identification General All...

Page 9: ...h fire To do so the gas pressure shall be adjusted at maximum nominal pressure as indicated on the data plate solenoid valves shall be in open or high fire position If desired the heat input of the he...

Page 10: ...olenoid valve S How to check correct operation of the burner Directly after ignition the burner flames are blue difficult to see during daylight After 15 seconds the ceramic burner stone starts glowin...

Page 11: ...metal spark wire and earthing wire still makes a 90 degrees angle directly above the ceramics and are not bending away to larger angles Clean the ignition device and check the connection of the igniti...

Page 12: ...ts by new ones Use a proper gas sealant to avoid gas leakage and seal the new parts Check the gas supply for the proper gas pressure and gas type and do a leakage test first Take the heater into opera...

Page 13: ...m Thermocouple and or magnetic coil of the safety device are broken Gas pressure lower than minimum requested Heater not suspended at 45 degrees angle facing downwards Not all burner stones are ignite...

Page 14: ...del you have For spare parts service material advice and information please contact the distributor Always mention the model name and serial number Service parts are only available via the distributor...

Page 15: ...Version 2 March 2020 15 manual 0009 0231EN Overview Parts AL 6...

Page 16: ...Version 2 March 2020 16 manual 0009 0231EN Overview Parts AL 7...

Page 17: ...15 Gas injection set AL 4 FSEi 10001013 10001023 10001033 10001043 10001053 10001063 10001073 Gas injection set AL 6 FSEi 10001113 10001123 10001133 10001143 10001153 10001163 10001173 Gas injection s...

Page 18: ...tion or the information is even not available Our advice is to stay first with the official listing as given in the table below In other cases check with the local gas authorities the data plate of th...

Page 19: ...1 60 1 60 2 00 15 37mm 5 0063CT3446 2K 2L G25 3 200 100 5 40 3 80 0 59 m3 h 1 00 1 00 1 00 10 5 37mm 5 0063CT3446 3P G31 50 25 4 50 3 20 322 g h 0 97 0 97 0 97 18 37mm 5 0063CT3446 3P G31 150 75 4 75...

Page 20: ...Version 2 March 2020 20 manual 0009 0231EN The local distributor...

Reviews: