Alke AL-4 Series User, Service And Installation Manual Download Page 19

Version 2: March 2020 

19 

manual: 0009 0231EN 

Technical table 

 

Gas group   Gas 

Max 

Supply 

pressure 

Min 

Supply 

pressure ** 

Max 

Heat Input 

Min 

Heat Input 

Gas 

consumption 

Main 

Injector 

Main 

Injector 

S-model 

By-pass 

hole ** 

S-model 

Venturi 

Injector 

Holder 

NOx 

Class 

Remarks  

(-) 

(-)* 

(mbar) 

(mbar) 

(kW Hs) 

(kW Hs) 

(g/h or m3/h) 

(mm) 

(mm) 

(mm) 

(mm) 

(-) 

(-) 

(-)  

AL-4 series

 

2E, 2E+, 2H  G20 

20 

12 

3,50 

2,70 

0,34 m3/h 

1,35 

1,35 

1,47 

18 

37mm 

0063CT3446 

2E, 2H 

G20 

200 

100 

3,50 

2,50 

0,34 m3/h 

0,76 

0,76 

0,76 

8,5 

37mm 

0063CT3446 

2LL 

G25 

20 

12 

3,50 

2,70 

0,39 m3/h 

1,49 

1,49 

1,85 

18 

37mm 

0063CT3446 

2K, 2L 

G25.3 

25 

15 

3,50 

2,70 

0,38 m3/h 

1,40 

1,40 

1,60 

13 

37mm 

0063CT3446 

2K, 2L 

G25.3 

200 

100 

3,50 

2,50 

0,39 m3/h 

0,82 

0,82 

0,82 

8,5 

37mm 

0063CT3446 

3P 

G31 

50 

25 

3,30 

2,30 

236 g/h 

0,84 

0,84 

0,84 

18 

37mm 

0063CT3446 

3P 

G31 

150 

75 

3,20 

2,30 

230 g/h 

0,64 

0,64 

0,64 

11 

37mm 

0063CT3446 

AL-6 series

 

2E, 2E+, 2H  G20 

20 

12 

4,50 

3,50 

0,43 m3/h 

1,53 

1,53 

1,90 

18 

37mm 

0063CT3446 

2E, 2H 

G20 

200 

100 

5,40 

3,80 

0,52 m3/h 

0,92 

0,92 

0,92 

10,5 

37mm 

0063CT3446 

2LL 

G25 

20 

12 

4,50 

3,50 

0,50 m3/h 

1,70 

1,70 

2,10 

18 

37mm 

0063CT3446 

2K, 2L 

G25.3 

25 

15 

4,70 

3,60 

0,51 m3/h 

1,60 

1,60 

2,00 

15 

37mm 

0063CT3446 

2K, 2L 

G25.3 

200 

100 

5,40 

3,80 

0,59 m3/h 

1,00 

1,00 

1,00 

10,5 

37mm 

0063CT3446 

3P 

G31 

50 

25 

4,50 

3,20 

322 g/h 

0,97 

0,97 

0,97 

18 

37mm 

0063CT3446 

3P 

G31 

150 

75 

4,75 

3,30 

340 g/h 

0,76 

0,76 

0,76 

12 

37mm 

0063CT3446 

AL-7 series

 

2E, 2E+, 2H  G20 

20 

5,90 

0,57 m3/h 

1,70 

23 

33-17mm 

0063CT3446 

2E, 2H 

G20 

200 

100 

6,20 

4,40 

0,59 m3/h 

0,95 

0,97 

0,98 

12 

33-12mm 

0063CT3446 

2LL 

G25 

20 

5,90 

0,66 m3/h 

1,87 

19 

33-17mm 

0063CT3446 

2K, 2L 

G25.3 

25 

15 

5,60 

4,35 

0,61 m3/h 

1,70 

1,72 

2,10 

18 

33-17mm 

0063CT3446 

2K, 2L 

G25.3 

200 

100 

5,80 

4,10 

0,63 m3/h 

1,03 

1,05 

1,10 

11 

33-12mm 

0063CT3446 

3P 

G31 

50 

25 

5,50 

3,90 

394 g/h 

1,05 

1,07 

1,10 

20 

33-17mm 

0063CT3446 

3P 

G31 

150 

75 

5,70 

4,05 

408 g/h 

0,82 

0,82 

0,82 

15 

33-12mm 

0063CT3446 

* G31 = propane, G20 = natural gas (100% methane), G25 = natural gas (86% methane); G25.3 = natural gas (88% methane) 
** In case the heater is equipped with a bypass hole (S version) the heater shall be operated on maximum supply pressure only. See also the pressure 
information on the data plate. 
 
Conversion calculation from gross heat input kW(Hs) to nett heat input kW(Hi): 
Propane: divide gross heat input kW(Hs) by factor 1,09 (example: 1,20 kW(Hs) / 1,09 = 1,10 kW(Hi) 
Natural gas: divide gross heat input kW(Hs) by factor 1,11 (example: 1,20 kW(Hs) / 1,11 = 1,08 kW(Hi) 
 
 

Summary of Contents for AL-4 Series

Page 1: ...L 7 Series Atmospheric ceramic gas infrared heaters for outdoor use Country of destination GB IE MT General international manual AL 7 SEi AS AL 4 F AS AL 6 FSEi AS Alke BV Industrielaan 11a 3925 BD Sc...

Page 2: ...Version 2 March 2020 2 manual 0009 0231EN Fig 1a Fig 1b Fig 1c Fig 1d Fig 2a Fig 2b Fig 3a Fig 3b Fig 4 Fig 5a Fig 5b Fig 5c Fig 6...

Page 3: ...the system is safe again Consult an installer If a heater is not safe to use anymore close the gas supply and electricity to the heater so that nobody accidentally can operate the heater Contact a ser...

Page 4: ...dealer in case the carton box and heater are damaged Before leaving the factory all the heaters are operated and tested by the manufacturer on gas for 5 minutes Note that due to this the burner and re...

Page 5: ...space The heaters are intended for outdoor use only or amply ventilated areas but not for indoor heating See fig 1a 1b 1c When local regulations allow it there are no safety objections to use the heat...

Page 6: ...objects Ventilation around the heater Check if there is sufficient space for the combustion gases to vent away but also if there is enough fresh air available at the inlet of the venturi 10 or 33 to t...

Page 7: ...connections of the gas regulator and the gas valve of the gas cylinder are of the same type Check with the gas cylinder supplier for the correct size of gas regulator and check whether the capacity is...

Page 8: ...er try to do gas repairs by yourself Do not use the heater anymore until the problem is solved 5 Electrical information only heaters with S Ei or SEi as a part of the model identification General All...

Page 9: ...h fire To do so the gas pressure shall be adjusted at maximum nominal pressure as indicated on the data plate solenoid valves shall be in open or high fire position If desired the heat input of the he...

Page 10: ...olenoid valve S How to check correct operation of the burner Directly after ignition the burner flames are blue difficult to see during daylight After 15 seconds the ceramic burner stone starts glowin...

Page 11: ...metal spark wire and earthing wire still makes a 90 degrees angle directly above the ceramics and are not bending away to larger angles Clean the ignition device and check the connection of the igniti...

Page 12: ...ts by new ones Use a proper gas sealant to avoid gas leakage and seal the new parts Check the gas supply for the proper gas pressure and gas type and do a leakage test first Take the heater into opera...

Page 13: ...m Thermocouple and or magnetic coil of the safety device are broken Gas pressure lower than minimum requested Heater not suspended at 45 degrees angle facing downwards Not all burner stones are ignite...

Page 14: ...del you have For spare parts service material advice and information please contact the distributor Always mention the model name and serial number Service parts are only available via the distributor...

Page 15: ...Version 2 March 2020 15 manual 0009 0231EN Overview Parts AL 6...

Page 16: ...Version 2 March 2020 16 manual 0009 0231EN Overview Parts AL 7...

Page 17: ...15 Gas injection set AL 4 FSEi 10001013 10001023 10001033 10001043 10001053 10001063 10001073 Gas injection set AL 6 FSEi 10001113 10001123 10001133 10001143 10001153 10001163 10001173 Gas injection s...

Page 18: ...tion or the information is even not available Our advice is to stay first with the official listing as given in the table below In other cases check with the local gas authorities the data plate of th...

Page 19: ...1 60 1 60 2 00 15 37mm 5 0063CT3446 2K 2L G25 3 200 100 5 40 3 80 0 59 m3 h 1 00 1 00 1 00 10 5 37mm 5 0063CT3446 3P G31 50 25 4 50 3 20 322 g h 0 97 0 97 0 97 18 37mm 5 0063CT3446 3P G31 150 75 4 75...

Page 20: ...Version 2 March 2020 20 manual 0009 0231EN The local distributor...

Reviews: