222 ~ 225MHz 30W RF Power Module
15) S-AV40 (XA1230)
BLOCK DIAGRAM
G H b
® RF Input (Pin)
(D Gate Voltage (VGG), Power Control
® Drain Voltage (VDD), Battery
(D RF Output (Pout)
© RF Ground (Frange)
ABSOLUTE MAXIMUM RATING ( Tc = 25 °C, unless otherwise noted )
Symbol
Parameter
Conditions
Ratings
Unit
VDD
Drain Voltage
VGG < 5V, Pi = 50mW, Po < 30W
17
V
VGG
Gate Voltage
VDD < 12.5V, Pin=50mW
6
V
IDD
Drain Current
8
A
Pin
Input Power
12.5V < VDD < 16.5V, VGG = 5V,
Pi = 50 mW
100
mW
Pout
Output Power
30
W
Tease (OP)
Operation Case Temperature
-30 to +100
°C
Tstg
Storage Temprature
-40 to +110
°C
ELECTRICAL CHARACTERISTICS ( Tc = 25°C, unless otherwise noted )
Symbol
Parameter
Conditions
Ratings
Unit
Min
Typ
Max
f
Frequency Range
220
246
MHz
Pout
Output Power
VDD = 12.5V
VGG = 5V
Pin = 50mW
30
W
V
T
Total Efficiency
40
%
2fo
2na Harmonic
-25
dBc
Pin
Input VSWR
3.0
-
IGG
Gate Current
1
mA
-
Stability
VDD=10.5-16,5V, VGG=0-5V, Pin=50mW,
Pout<30W (VGG control),
Load VSWR=3:1 ALL PHASE
All sprious output
than 60dB bellow
desired signal
-
-
Load VSWR
Tolerance
VDD=15.0V, Pin=50mW,
Pout=30W (VGG control),
Load VSWR=10:1 ALL PHASE
No degradation
All manuals and user guides at all-guides.com
Summary of Contents for DR-235
Page 17: ...V All manuals and user guides at all guides com ...
Page 19: ...FF0017 EXPLODED VIEW 1 LCD Assembly ST0064 All manuals and user guides at all guides com ...
Page 33: ...1 DR 235 d e n jt BLOCK DIAGRAM All manuals and user guides at all guides com ...
Page 35: ...3 MAIN Unit Side A DR 235 UP0579 All manuals and user guides at all guides com ...
Page 39: ...2 MAIN Unit DR 235 All manuals and user guides at all guides com ...
Page 40: ...TNC Unit OPTION Unit EJ41U GPS P IT DATA CONECT All manuals and user guides at all guides com ...