48
4) Rx Test Specification
TEST ITEM
CONDITION
ADJ STANDARD
TEST STANDARD
NOTE
136.05MHz
146.05MHz
173.95MHz
Less than -7dBu
Less than -8dBu
Less than -6dBu
Less than -6dBu
Less than -7dBu
Less than -5dBu
146.05MHz
NARROW
Less than -8dBu
Less than -7dBu
12dBSINAD
RX Sensitivity
135.05MHz
Less than 9dBu
Less than 10dBu
AM 10dB S/N
WIDE
RX Distortion
NARROW
Less than 4%
Less than 5%
SSG OUT PUT 30dBu
WIDE
More than 40dB
More than 38dB
RX S/N
NARROW
More than 34dB
More than 32dB
SSG OUT PUT 30dBu
0.3~3KHzBPF OFF
Squelch Open
Squelch Open
SSG Output -10dBu
Squelch
Sensitivity
146.05MHz
Indication 02
Squelch Close
Squelch Close
SSG Output OFF
S Meter
146.05MHz
1KHz
3.5KHz/DEV
All
20dBu
All
25dBu
Decrease
and
level
AF Output
146.05MHz
More than 2W
More than 2W
SSG Output 30dBu
WIDE
500Hz/DEV
Open at
500Hz/DEV
CTCSS
Sensitivity
NARROW Open
at
250Hz/DEV
Open at
250Hz/DEV
SSG Output 0dBu
88.5Hz
WIDE
Opens when Test
Equipment
Tx
Opens when Test
Equipment
Tx
255 code
DCS Sensitivity
NARROW
Opens when Test
Equipment
Tx
Opens when Test
Equipment
Tx
255 code
Drain Current
146.05MHz
Less than 0.65A
Less than 0.65A
MAX VR
Power
Current
146.05MHz
Less than 10mA
Less than 10mA
Power Off
Howling 146.05MHz
Don’t occur
Don’t occur
SSG Output 60dBu
MOD OFF MAX VR
Open at
appears at
appears at
SSG level
decrease S Meter
is in
is in
is in
is in
Off
Summary of Contents for DR-135
Page 14: ...14 12 M3826M8L269GP XA0818 CPU Terminal Connection TOP VIEW 269 ...
Page 23: ...23 11 M57788M XA0077 ...
Page 59: ...59 3 MAIN Unit Side A DR 135 UP 0400B 4 MAIN Unit Side B DR 135 UP 0400B ...
Page 67: ...67 5 TNC Unit DR 135TP only or option CN6 CN7 TO MAIN CN107 ...
Page 68: ...68 BLOCK DIAGRAM 1 DR 135 ...
Page 69: ...69 2 DR 235 Downloaded by RadioAmateur EU ...
Page 70: ...70 3 DR 435 ...