Using the Waterproof Ethernet Fitting
Install the
Waterproof Ethernet Fitting
on the Ethernet cable end at the camera when moisture or
contamination exists in the area near the camera. The fitting includes several parts that must be installed in
a specific order. To install the fitting:
1.
Place the rubber O-ring over the camera drop cable end cap.
Push the O-ring up to the connector cap.
2.
Place the Lock Nut onto the network cable from the router or
switch as shown in the drawing to the right. The inside threads
must be toward the camera end.
3.
Place the rubber basket onto the network cable above the lock
nut as shown.
4.
Place the end cap onto the network cable above the rubber
gasket as shown. The fingered end must be toward the router
or switch.
5.
Crimp the RJ-45 connector onto the network cable.
6.
Plug the RJ-45 connector with the network cable into the
camera network drop cable.
7.
Fit the end cap on the network cable onto the camera drop cable
end cap. Rotate the network cable end cap to lock it in place.
8.
Push the rubber gasket fully into the end of the network cable
end cap.
9.
Screw the lock nut onto the network cable end cap until it is
fully seated.
Network drop
cable from
camera
Network cable from
router or switch
Fitting assembled
Waterproof Ethernet Fitting assembled and connected
Drop cable
end cap
Network drop
cable from
camera
Rubber
O-ring
seal
RJ-45
connector
End cap
Rubber
gasket
Network
cable
from
router or
switch
Lock nut