6. Installation
Installation position of Vortex Flowmeter is very important. It concerns measuring accuracy. Please leave more space of
straight pipe in upstream and downstream as best as you can. If not permitted, please install as 2/3 of total straight pipe
length on the upstream and 1/3 on downstream. However, accuracy this time can not be assured as factory accuracy.
For example:
20D
5D
20D
5D
50D
5D