RINSE
INJECTION
DETERGENT
INJECTION
WASH
SENSOR
RINSE
SENSOR
3
-202
1
180UC
Quick Setup
Instructions
1
STEP
FLOOR DRAIN
1"AIR GAP
Connect the drain hose to wall, not higher than 22
inches, or floor drain. The floor drain must have a
1 inch air gap between drain hose and floor drain.
WALL
DRAIN
WARNING
: Electrical and plumbing
connections need to be made by a
qualified service technician and
comply with all available Federal,
State and Local Health, Electrical,
Plumbing and Safety codes.
1/2" WATER INLET
DRAIN VALVE
PUMP DRAIN
MOTOR
LEVELING
LEGS
2
3
4
4
Connect dishmachine to hot water source,
recommended minimum temperature 140°F. Unit will
remain in wash cycle until booster heater
temperature reaches 180°F, then it will advance into
rinse cycle.
3
STEP
When ever possible,
remove pump drain
if a floor
drain is available near by. Remove drain pipe and
place drain hose on the drain valve and allow
machine to gravity drain.
4
STEP
NEUTRAL
HOT
GROUND
DRAIN HOSE
1
HARD WIRE
FOUR WIRE
POWER SUPPLY
180UC REAR VIEW
NOT MORE
THAN 22"
HEIGHT FROM
FLOOR
BLUE
RED
TUBE
STIFFENER
CHEMICAL
TUBING
5
Insert tube stiffener with chemical tubing into
corresponding chemical dispensers.
5
STEP
BLUE
RED
Level dishmachine by adjusting leveling legs.
Dishmachine must be level front and back and
side to side.
2
STEP