ALGE-Timing D-LINE Series Manual Download Page 4

 Manual 

D-LINE

 

 

1  Operation 

1.1 

Change the Displaymode 

You can change the Displaymode with the internal button or with the PC-Software and the 
cable 145-05. 
To change the parameters with the internal button you have to press the button as long as 
the first parameter appears on the display. If you wait now for a few second the Value of the 
parameter starts blinking. You can now always change the parameter or value which is 
blinking. To save the changings you need to push through all the parameters. 

1.2 

Standard-Settings 

The D-LINE Scoreboards are delivered with a standard-setting optimized to show the running 
time from the Timing-Device. 
To reload the Factory settings keep the internal button pressed as long as the Software-
Version appears on the display! 
ATTENTION! Only Scoreboards newer than 2005-06 have this function! 

1.3 

Parameterlist 

The parameterlist shall be in a way that the user can already see by the name of the 
parameter that he is adjusting the parameter he would like to adjust. On the side there shall 
be also a sticker with a short explanation.  
 
ATTENTION! Old D-LINE models have different parameters. These old parameters are 
always in [xx]. Some of the settings are identically and some others are not available. 
 
ATTENTION! Since 3-digit-displays doesn’t have the full capability of all the below described 
functions there is a different menu for these displays. 
You can find these parameters in () behind the normal parameters! Non described 
parameters are not available on such displays! 

1.3.1 

 Set daytime hours [P0] 

This parameter is to adjust the hours of the daytime 

1.3.2 

 Set daytime minute [P1] 

This parameter is to adjust the minutes of the daytime. 

1.3.3 

 Set daytime seconds [P2] 

This parameter is to adjust the minutes of the daytime. 

1.3.4 

 Set the day of the date [P3] 

This parameter is to adjust the day of the date. 

1.3.5 

 Set the month of the date [P4] 

This parameter is to adjust the month of the date. 

Page 4 

 

 

Summary of Contents for D-LINE Series

Page 1: ...Manual Version E070920...

Page 2: ...Manual D LINE Page 2...

Page 3: ...l interface setting A1 S 8 1 3 15 Time out for daytime A2 9 1 3 16 Address Setting A3 A 9 1 4 Extended Datamode 10 1 4 1 Timer S4 Points Showjumping 10 1 4 2 TdC8001 Points Showjumping 11 1 4 3 Fixed...

Page 4: ...shall be in a way that the user can already see by the name of the parameter that he is adjusting the parameter he would like to adjust On the side there shall be also a sticker with a short explanat...

Page 5: ...eter you can adjust the offset to GMT i9n minutes 1 3 12 Area settings for temperature and time Area parameter in order to adjust the diplaymode for time and temperature Following settings are possibl...

Page 6: ...mode and temperature in Celsius 1 3 12 2 4 Celsius and 12h x1 Time in 12h mode and temperature in Celsius but on 6 Digit D Line time is centered and without running seconds 1 3 12 2 5 Fahrenheit and 2...

Page 7: ...ted 1 3 13 2 Second Digit of Setting This setting is defining the brightness mode of the display 1 3 13 2 1 Manual setting The second digit of the brightness setting can be adjusted from 0 to 9 for ma...

Page 8: ...1 5 Extended Mode 4x This is an advanced mode where you can configure the complete scoreboard by yourself You can define which byte shall be shown on which position of the display board If the serial...

Page 9: ...rameter described from point 1 3 1 to point 1 3 12 2 7 are not visible anymore If you set this time to 0 the Time Temp Date function is disabled Up to Version 3 7 it is in seconds andfrom Version 3 8...

Page 10: ...3 24 PZ PE H H M M S S z Pz Pe CR PZ PE H H M M S S z h t Pz Pe CR The parameters should be adjusted like this Extended protocol 2400bps A1 40 S E2 Device adress 00 A3 00 A 00 First digit is always in...

Page 11: ...is always inactive A8 00 Third digit will display points PE A9 02 Will show the dot which is sent after the full second B0 17 Fourth Digit will show points Pz B1 21 Dot or double dot after fourth dig...

Page 12: ...Stopwatch and Countdown 2 1 1 2 mm ss zh A1 1x Timeformat for Stopwatch and Countdown 2 1 1 3 Adjusting the Countdown time After you have reached the Countdown mode by pressing the manual button for...

Page 13: ...lue 3 Technical Data 3 1 Dimensions Type Amount of digits Figure Height Height Width Deep Hangers max Dist Power W D LINE57 I 3 E0 3 57 130 400 60 200 25m 10 D LINE57 I 4 E0 4 57 130 400 60 200 25m 11...

Page 14: ...onnections Internal button to change the display mode Amphenol Socket 1 10 to 12 Volt 2 Ground 3 Data Out E Data In Connection for manual button Stopwatch Countdown Data In and Ground 100 240V 50 60Hz...

Page 15: ...E TdC 4000 Identifier for ending time at fourth digit D ALGE TdC 4000 Identifier for total time at fourth digit K Comet 1 Start channel 2 Start channel 4 Stop channel or 8 Stop channel Tc Timer identi...

Page 16: ...Manual D LINE Page 16...

Page 17: ...Manual D LINE Page 17 3 3 2 RS485 This interface is optional available with customized protocols 3 3 3 Ethernet This interface is optional available with customized UTP Protocol...

Page 18: ...Manual D LINE Page 18 4 Comments...

Page 19: ...Manual D LINE Page 19...

Page 20: ...Manual D LINE Page 20...

Reviews: