Manual
D-LINE
1.4
Extended Datamode
In this mode you can assign each digit one byte out of the datastring.
It is for example possible to program it so that you can see on one 6-digit scoreboard the BIB on the
first 2 digits and the time in m:ss on the last 3 digits.
In some sports like equestrian (with the Timer S4) you have to program the display for the points in
this mode.
1.4.1 Timer S4, Points Showjumping
Configuration of a 6-digit display in order to show the points, sent by a Timer S4 (equestrian) in the
middle of the display.
The datapackage of the Timer S4 looks as desribed below:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
PZ PE .
H H
:
M
M
:
S
S
.
z
Pz Pe CR
PZ PE
H H
:
M
M
:
S
S
.
z
h
t Pz Pe CR
The parameters should be adjusted like this:
Extended protocol, 2400bps [A1-40] (S-E2)
Device adress 00 [A3 00] (A-00)
First digit is always inactive [A5-00]
Dot or double-dot after first digit is always inactive [A6-00]
Second digit will display points PZ [A7-01]
dot or double-dot after second digit is always inactive [A8-00]
Third digit will display points PE [A9-02]
Will show the dot which is sent after the full second [B0-17]
Fourth Digit will show points Pz [B1-21]
Dot or double-dot after fourth digit is always inactive [B2-00]
Fifth digit will show points Pe [B3-22]
Dot or double-dot after fifth digit is always inactive [B4-00]
Sixth digit is always inactive [B5-00]
In the older Models of the D-LINE, the first digit is A5 and then it is continuing with A6-A9, after
A9 it starts with B0….