alfen 904461001 Manual Download Page 6

6

Eve model 2017 (2.0) manual | Version 1.0 | July 2017 

ENGLISH

TABLE OF CONTENTS

DECLARATION OF CONFORMITY 

Safety and usage instructions 

7

1.1 

Purpose and intended audience  

7

1.2 

General safety 

7

2 Product 

8

2.1 

The charging station 

8

2.2 

Status indications on the display 

8

2.3 

Operating the charging station 

9

2.4 

Technical specifications 

9

2.4.1  Eve 2017 model overview 

10

2.4.2  Input / electricity grid connection 

11

2.4.3  Output / vehicle connection 

11

2.4.4  Protection / integrated components 

11

2.4.5  Charging and access 

12

2.4.6  Operating conditions 

12

2.4.7 Casing 

12

2.5 

Optional factory settings 

13

2.6 Accessories 

13

Installing and connecting 

14

3.1 

Installing and connecting 

14

3.2 

Assembly and installation requirements 

14

3.3 

Mechanical installation 

14

3.4 

Electrical installation 

16

Commissioning the charging station 

18

4.1 

Safety instructions prior to usage 

18

4.2 Commissioning 

18

5 Connectivity 

19

5.1 

Administration systems 

19

5.2 

Establishing a connection 

19

5.2.1  Wireless connection 

19

5.2.2  UTP (Ethernet) connection 

19

5.3 

Registering your  ICU EZ account 

20

5.4 

Registering your charging station within 

 

your own administration system 

28

Appendices

Appendix 1: Error codes and problem solving 

21

Appendix 2: Default configuration of optional 
factory settings 

22

Manufacturer information:

Alfen ICU B.V.
Hefbrugweg 28
1332 AP Almere
The Netherlands

Declares the conformity of the product:

Charging stations of the type Alfen Eve

Pursuant to European directives:

Low Voltage Directive 2014/35/EU 
EMC Directive 2014/30/EU

Applied (harmonised standards)

• 

NEN-EN-IEC 61851-1

• 

NEN-EN-IEC 61851-22

• 

NF-EN-IEC 61851-1

• 

NF-EN-IEC 61851-22

• 

DIN EN 61851-1

• 

DIN EN 61851-22

• 

BS EN 61851-1

• 

BS EN 61851-22

• 

CEI EN 61851-1

• 

CEI EN 61851-22

All mentioned products are labelled with the CE mark.

Almere, The Netherlands, 3 juli 2017

M. Roeleveld, Msc.

Summary of Contents for 904461001

Page 1: ...Eve TM Model 2017 2 0 Manual Handboek Handbuch Manuel...

Page 2: ...2 OUTSIDE BUITENZIJDE AUSSENSEITE EXT RIEUR 1 3 5 6 7 5 2 4 6 5 8...

Page 3: ...3 INSIDE BINNENZIJDE INNENSEITE INT RIEUR 9 13 10 9 11 12 14...

Page 4: ...4...

Page 5: ...lly utilise all advanced features of your new system we advise you to read this manual carefully Properly store this manual for future usage We have invested a great amount of care to provide you with...

Page 6: ...rging station 18 4 1 Safety instructions prior to usage 18 4 2 Commissioning 18 5 Connectivity 19 5 1 Administration systems 19 5 2 Establishing a connection 19 5 2 1 Wireless connection 19 5 2 2 UTP...

Page 7: ...eral safety DANGER The safety instructions are intended to ensure proper practical usage If you do not comply with these safety regulations and instructions you may expose yourself to the risk of elec...

Page 8: ...lour display to visualise the status of the charging station and inform the user about the charging progress 23 10 2017 12 30 Please hold card over reader below To stop charging please hold card over...

Page 9: ...1 0 July 2017 ENGLISH 2 PRODUCT 2 3 Operating the charging station Plug Charge No charge card authorisation required RFID Charging station with user authorisation Start Stop Start 1 1 1 1 2 2 2 2 3 3...

Page 10: ...site short circuit protection For 2x3 7kW 11kW 40A B residual current fuse or 35A gG fuses Load balancing optional For 2x7 4kW 22kW 40A B residual current fuse or 35A gG fuses Load balancing required...

Page 11: ...7 4kW charging 32A selected per phase 904461011 3 x 6mm2 904461012 3 x 6 mm2 per cable 3 phase 22kW charging 32A selected per phase 904461001 5 x 6 mm2 904461002 5 x 6 mm2 per cable Nominal current 23...

Page 12: ...ay have an adverse effect on the temperature range The temperatures mentioned above apply for the ambient temperature of the product assuming the standard colour of the casing RAL9016 Other darker col...

Page 13: ...e RFID Maximum available charging current per socket 16A 32A Smart charging options Off Standard load balancing Active load balancing P1 Own logo shown on colour display Off Alfen logo On Your own log...

Page 14: ...omponents that may still contain electrical charge after being disconnec ted Wait at least 10 seconds after disconnection before commencing work DANGER The electric system must be entirely disconnecte...

Page 15: ...side of the charging station is covered to prevent it from being unintentionally disconnected or used by unauthorised individuals 3 3 Mechanical installation Use the following tools and equipment to i...

Page 16: ...instance in the packaging of the Eve Be particularly careful with the display screen Image 3 Location of Torx T25 bolts to release adjust and fasten the enclosure Installing the charging station 1 Pl...

Page 17: ...ide the charging station are enabled 9 Put the isolating switch on the I ON position If useful use a special wrench to simplify switching 10 Press the white part of the casing in the orifices on the t...

Page 18: ...llowing actions are performed 1 The display briefly illuminates and then switches off 2 The sockets are tested individually testing locking testing internal relays switching is audible 3 The display b...

Page 19: ...allation is complete always verify the signal strength using the Service Installer REMARK A connection with an administration system can only be established if you made arrangements with the supplier...

Page 20: ...he Alfen website 2 Please fill in the numbers on the back of the charge cards delivered to you in the Remarks field 3 Click on Send 4 Alfen will process your application and activate your account You...

Page 21: ...ug You can now start a new session 007 Charging error vehicle will not shut down Contact the service department the vehicle might not be responding correctly 101 Residual current device deactivated Co...

Page 22: ...ommunicate with each other over the P1 port using the DSMR protocol version 4 0 or higher Data about the actual consumption and charging needs is regularly exchanged Whenever smart meter capacity is l...

Page 23: ......

Page 24: ...kt Contact Alfen ICU B V Hefbrugweg 28 1332 AP Almere The Netherlands P O box 1042 1300 BA Almere The Netherlands Tel Sales Support 31 0 36 54 93 402 Tel Service 31 0 36 54 93 401 Website ww alfen com...

Reviews: