Alfatron ALF-21E-CODEC
18
Command
Description
Command & Feedback
Example
#SET_AM_[PARAM1]_
[PARAM2]:XXXX
Set the ASCII RS232 command
XXXX
to
be sent to control the third-party device
when the
VOLUME MUTE
button is
pressed.
[PARAM1] = 00~06 (Baud Rate)
00 - 115200
01 - 57600
02 - 38400
03 - 19200
04 - 9600
05 - 4800
06 - 2400
[PARAM2] = 00~99. The delay time
of sending command.
XXXX: Any ASCII code (up to 48
bytes).
#SET_AM_05_30:ABCDEFG
@BAUDRATE: 4800
@DELAY TIME: 30 s
@VOLUME MUTE TO
SEND:ABCDEFG
#SET_H_AM_[PARAM1]_
[PARAM2]:XX XX
Set the HEX RS232 command
XX XX
to
be sent to control the third-party device
when the
VOLUME MUTE
button is
pressed.
[PARAM1] = 00~06 (Baud Rate)
00 - 115200
01 - 57600
02 - 38400
03 - 19200
04 - 9600
05 - 4800
06 - 2400
[PARAM2] = 00~99. The delay time
of sending command.
XX XX: Any HEX code (0-9, A-F; up
to 20 bytes. It must have a blank
between 2 different XX).
#SET_H_AM_05_30:31 32
33 34 35
@BAUDRATE: 4800
@DELAY TIME: 30 s
@VOLUME MUTE HEX TO
SEND:31 32 33 34 35