KITCHEN STOVE INSTALLATION, USE AND OPERATING INSTRUCTIONS 

 
These  installation,  use  and  operating  instructions  are  applicable  only  for  the  following  kitchen  stove 
type: 

ALFA 55 

Before using the stove for the first time: 
 

*  In  order  to  ensure  uninterrupted  operation  of  the  stove,  you  must  carefully  read  these  Instructions 
before using the stove for the first time and comply with the specified recommendations.  
 
* Use only the recommended types of fuel, such as logs and brown coal briquettes. In connection to 
the allowed types of fuel, please refer to 1

st

 Federal Emission Protection Decree. 

 
*  Required  discharge  pressure  in  the  chimney  under  normal  operating  load  must  equal  12  Pa.  For 
discharge pressure exceeding 15 Pa, a damper needs to be installed inside the draft air duct.  
 
* Inside the room where the stove is to be installed, sufficient fresh air supply needs to  be provided. If 
windows and doors in the room are well sealed when shut, or if air consuming appliances are installed 
in  the  same  room  (such  as  extractor  hoods,  tumble  dryers  etc.)  fresh  air  should  be  occasionally 
introduced into the room (by opening the doors and windows). In any event, before installing the stove, 
consult a chimney sweeper.     
 
* Combustible materials cannot be disposed in the ash pan. Ash layer height cannot exceed the height 
of the side walls.  
Firebox and ash pan door must be kept closed at all  times (except while  lighting the fire, adding fuel 
and removing ash), so as to prevent escape of hot gas.  
 
Modifications  cannot  be  made  to  the  stove,  unless  original  parts  are  used  which  have  been  made 
available  and  tested  by  our  company,  or  if  modifications  are  made  by  a  representative  of  the 
manufacturer’s customer service. 
 
In the event of fire inside the flue duct, keep the stove doors closed and shut the air regulators. Never 
extinguish the fire inside the flue duct using water. An explosion may occur inside the flue duct due to 
rapid formation of vapor. In the event of an emergency, call the fire department!  
 
In the event of faulty operation, shut all air regulators and do not add any more fuel until the necessary 
repairs are done.  
 
During  construction  of  the  structure  and  the  chimney,  relevant  civil  engineering  and  fire  protection 
regulations  must  be  complied  with,  as  well  as  all  local,  national  and  European  regulations  and 
standards. 
 
 

SPECIFICATIONS 
                                                                                                                                          

ALFA 55 

Nominal heating power..........................................................................................................5 KW

 

Flue gas temperature (logs/ brown coal briquettes).....................................................195/175 

°C 

Flue gas flow (logs/ brown coal briquettes)....................................................................8,8/8,4 g/s 
Necessary pressure (logs/ brown coal briquettes)...........................................................12/13 Pa  
Stove dimensions (width x depth x height)  )................................................. 965 x 612 x 755 mm 
Oven dimensions (width x depth x height)  ................................................... 550 x 540 x 195 mm 
Flue duct connection diameter    .......................................................................................120 mm 
Height from floor to center of duct connection..............................

...........................bočno 590 mm 

Weight...................................................................................................................................91 kg 
 
 
 
 
 
 