KITCHEN STOVE INSTALLATION, USE AND OPERATING INSTRUCTIONS
These installation, use and operating instructions are applicable only for the following kitchen stove
type:
ALFA 55
Before using the stove for the first time:
* In order to ensure uninterrupted operation of the stove, you must carefully read these Instructions
before using the stove for the first time and comply with the specified recommendations.
* Use only the recommended types of fuel, such as logs and brown coal briquettes. In connection to
the allowed types of fuel, please refer to 1
st
Federal Emission Protection Decree.
* Required discharge pressure in the chimney under normal operating load must equal 12 Pa. For
discharge pressure exceeding 15 Pa, a damper needs to be installed inside the draft air duct.
* Inside the room where the stove is to be installed, sufficient fresh air supply needs to be provided. If
windows and doors in the room are well sealed when shut, or if air consuming appliances are installed
in the same room (such as extractor hoods, tumble dryers etc.) fresh air should be occasionally
introduced into the room (by opening the doors and windows). In any event, before installing the stove,
consult a chimney sweeper.
* Combustible materials cannot be disposed in the ash pan. Ash layer height cannot exceed the height
of the side walls.
Firebox and ash pan door must be kept closed at all times (except while lighting the fire, adding fuel
and removing ash), so as to prevent escape of hot gas.
Modifications cannot be made to the stove, unless original parts are used which have been made
available and tested by our company, or if modifications are made by a representative of the
manufacturer’s customer service.
In the event of fire inside the flue duct, keep the stove doors closed and shut the air regulators. Never
extinguish the fire inside the flue duct using water. An explosion may occur inside the flue duct due to
rapid formation of vapor. In the event of an emergency, call the fire department!
In the event of faulty operation, shut all air regulators and do not add any more fuel until the necessary
repairs are done.
During construction of the structure and the chimney, relevant civil engineering and fire protection
regulations must be complied with, as well as all local, national and European regulations and
standards.
SPECIFICATIONS
ALFA 55
Nominal heating power..........................................................................................................5 KW
Flue gas temperature (logs/ brown coal briquettes).....................................................195/175
°C
Flue gas flow (logs/ brown coal briquettes)....................................................................8,8/8,4 g/s
Necessary pressure (logs/ brown coal briquettes)...........................................................12/13 Pa
Stove dimensions (width x depth x height) )................................................. 965 x 612 x 755 mm
Oven dimensions (width x depth x height) ................................................... 550 x 540 x 195 mm
Flue duct connection diameter .......................................................................................120 mm
Height from floor to center of duct connection..............................
...........................bočno 590 mm
Weight...................................................................................................................................91 kg