ALFAMATIC CSQ-Visual Installation Manual Download Page 13

13 

 

Example of wiring of three sensors (selection of 5 to 8 works): 

 

2.1.2  Selection through serial command 

The 

CSQ-Visual

  supports  serial  communication  through  which  it  is  possible  to  select  a  work 

remotely.  Using  serial  communication,  it  is  possible  to  select  up  to  250  works.  To  be  able  to 
operate it is necessary to enable slow serial communication and set the 

Automatic selection code

For the use of serial communication, see the relative manual. 

2.2  Configuring the use of the phases 

It is sometimes necessary to perform different machining process on the same piece, for instance, 
different gears are fitted onto a drive shaft one after the other: hence the need to analyse all the 
different machining phases.  
The 

CSQ-Visual 

is able to manage up to four phases for each single process. The choice of the 

phase may take place automatically, in succession or through the digital inputs of the instrument.  
For every work process is it possible to decide whether to exclude one or more phases. 
To enable a function for several phases, it is necessary to indicate the maximum number of phases 
supported.  To  do  this,  select  the 

TOOLS  >  ADVANCED  OPTIONS  >  MACHINE  TYPE  >  WORKS 

PHASES  CHANNELS

  menu  and  change  the 

Number  of  phases

  value.  As  well  as  indicating  the 

number of phases, it is necessary to indicate the way to behave, changing the 

Automatic selection 

code

If the maximum number of phases is changed, it will be necessary to cancel all the works created 
previously: 

 

Figure 2 

Summary of Contents for CSQ-Visual

Page 1: ...Mar 7 2017 CSQ Visual Version with VIO9 card Installation manual...

Page 2: ...2...

Page 3: ...of the instrument 4 1 3 Internal cards 5 1 4 Electric wiring 5 2 Special functions 12 2 1 Configure automatic work selection 12 2 2 Configuring the use of the phases 13 2 3 Connection of an external...

Page 4: ...lter and be controlled using semiconductor devices Always connect the container of the instrument to the earth conductor 1 2 Operating of the instrument Attention the CSQ Visual is not and could not b...

Page 5: ...strument s inputs and outputs must be the same that powers the inputs and outputs of the PLC We recommend the use of at least one output START signal and three inputs of the PLC GO GOOD and REJECTED I...

Page 6: ...t of the card Figure 1 Main power terminal block X24 The electronics of the CSQ Visual and the transducers are powered at 24VDC via the X24 three pole terminal block Name Function Terminal 0VDC Negati...

Page 7: ...y a jobs see 2 PHASE SELECTOR The binary value of these inputs select automatically the phase of job BASKET 1 2 Input for sensor for the detection of normal rejected basket BASKET 2 3 Input for sensor...

Page 8: ...f the cylinder until the next start The output is intermittent until the reset signal PRESS 2 Enables the press Active after the start if the instrument is ready and deactivated upon reaching the stop...

Page 9: ...put is internal connected to 0V 10V X12 7 10V potentiometer power 10mA max POT X12 8 Positive analog differential input potentiometer cursor with J4 this imput accept 0 20mA signal Electrical features...

Page 10: ...J10 Load cell 2mV V supply 10V push only A A OUT A Load cell 2mV V supply 10V push pull B OUT OUT A Load cell 2mV V supply 5V push pull A OUT OUT B Analog input 0 10V OUT B IN A Analog input 0 5V OUT...

Page 11: ...Q Visual Pin 3 TX interface output signal from the CSQ Visual Pin 5 GND Optional analog outputs X16 Nome Morsetto Descrizione CLK X16 1 Do not connect CLK X16 2 Do not connect DIR X16 3 Do not connect...

Page 12: ...m the work selected automatically to create an extra work and use a work other than that selected automatically the unlock password in required Automatic selection only works if the instrument START i...

Page 13: ...after the other hence the need to analyse all the different machining phases The CSQ Visual is able to manage up to four phases for each single process The choice of the phase may take place automatic...

Page 14: ...nic sensor with a PNP positive logic output 2 4 SETPOINT output The CSQ Visual has an auxiliary output which can be activated when a determined absolute position or a determined force have been reache...

Page 15: ...the internal cards by a few centimetres Then release the cards from the front panel Figure 4 Pull out all the cards from the container and remove the five terminal block units To fasten the instrumen...

Page 16: ...card Lastly insert the terminal block units paying attention to the direction Make sure that cables are not squashed on the bottom of the instrument After completing the wiring it is possible to suppl...

Reviews: