Check whether the chimney size is too big and whether the flame reaches the chimney top. 

 

9.

 

The Nameplate 

 

The nameplate is attached to the back or the bottom of stove, containing serial number that should be listed for each order. 

 

 
 
 
 
 
 
 

Summary of Contents for Elita

Page 1: ... ELITA ELITA II This product meets the requirements of the Ecodesign Directive in terms of efficiency and air pollution level in order to contribute to the reduction of energy consumption and negative environmental impact INSTRUCTIONS FOR INSTALLATION AND USE ENG_v 2 0 ...

Page 2: ...ith the effective construction rules and regulations on firebox as well as all required local national and European standards Important notes Never manipulate fireplace by holding cast top plate The fireplace should be manipulated only while it is packed The packed stove should be brought to the location where it would be installed and only then it should be unpacked figure 1 It should be moved by...

Page 3: ...s 15 Pa throttle valve spacer should be used for the discharge pipe Figure 8a and 8b The ashpan must not contain any flammable materials The filling level should not exceed the height of lateral sides to the ashpan Caution The door and the section containing ash should always be closed except in lighting fire fuel supply and cleaning up ash to prevent the escape of hot air It is not allowed to do ...

Page 4: ...regulation 1 3 1 Primary air 1 3 2 Use of knobs on firebox door 1 4 Stove installation 2 5 Stove commissioning 3 5 1 Stove commissioning and stove operation 3 5 2 Stove maintenance and cleaning 3 6 General data 4 7 Frequently Asked Questions 4 8 The Nameplate 5 ...

Page 5: ...cted air intake The secondary air intake is on the stove door The secondary air supplies fire with the oxygen needed for clean combustion burning of previous incomplete combustion products Due to poor oxygen intake a great emission of harmful substances occurs which can lead to blockage of the flue 3 1 Primary air Reliable fuel combustion is determined based on the primary combustion air This air ...

Page 6: ... if the cast panel is used During the installation of used air drain pipe it is necessary to secure the distance of at least 50 cm away from flammable materials Before the stove is connected to the chimney it is mandatory to consult the local competent chimney sweeping organization The flue stove connection is done through the connecting elements according to SRPS M R4 031 DIN 1298 or DIN EN 1856 ...

Page 7: ...vement of certain amount of smoke If adding fuel the door should be opened carefully to eliminate smoke This method stops smoke from entering the room Nominal heat output is achieved with the following fuel quantities and the primary air control damper settings Fuel type Fuel quantity Combustion time Air control on the stove door near the ashpan kg h Degree wood logs 1 8 1 15 cm open The stove may...

Page 8: ...n high temperatures such sediments could ignite with severe consequences to the chimney and the entire house caused by improper behavior Figure 8 Shaking of the grate is performed via the knobspresented on figure 5 6 General data If you adhere to the instructions for installing and use of the stove this stove will be a reliable source of heat All problems with Your stove can be resolved by our ser...

Page 9: ...er the chimney size is too big and whether the flame reaches the chimney top 9 The Nameplate The nameplate is attached to the back or the bottom of stove containing serial number that should be listed for each order ...