5 Maintenance
Maintain the valve/actuator regularly. Study the instructions carefully and pay special attention to the warnings!
Always keep spare rubber seals and guide rings in stock. The items refer to the parts list and service kits section.
The valve is designed so that internal leakages do not result in the products becoming mixed.
Internal leakage in the valve is externally visible. Check the valve for smooth operation after service.
Recommended spare parts: Service kits
Order service kits from the service kits section
Ordering spare parts: Contact the Sales Department.
Valve rubber seals
Valve plug seals
Valve guide rings
Preventive maintenance
Replace after 12 months(*)
Replace after 12 months(*)
Replace when required
Maintenance after leakage
(leakage normally starts slowly)
Replace after production
cycle
Replace after production
cycle
Planned maintenance
-
Regular inspection for
leakage and smooth
operation
-
Keep a record of the valve
-
Use the statistics for
inspection planning
-
Regular inspection for
leakage and smooth
operation
-
Keep a record of the valve
-
Use the statistics for
inspection planning
Replace when required
Lubrication
When assembling
Klüber Paraliq GTE 703 or
similar USDA H1 approved
oil/grease (**) (suitable for
EPDM)
When assembling
Klüber Paraliq GTE 703 or
similar USDA H1 approved
oil/grease (**) (suitable for
EPDM)
None
NOTE!
Lubricate thread in valve plug parts with Klüber Paste UH1 84-201 or similar.
(*) Depending on working conditions! Please contact Alfa Laval.
(**) All products wetted seals.
Repairing of actuator:
-
The actuator is maintenance-free but repairable.
-
If repair is required, replacing all actuator rubber seals is recommended.
-
Lubricate seals with Klüberplex BE31.
-
To avoid possible black marks on pos. 1 and 29, Alfa Laval recommends Klüber Paraliq GTE703 (white) for these two
positions.
23
Summary of Contents for Unique Mixproof LP
Page 2: ......